Table 3. Suggested Locations for Best Reliability
•
Do not locate close to bedrooms as operational sounds may be
objectionable.
•
Avoid locations near windows and similar areas where
condensation and freezing defrost vapor can annoy a customer.
•
The
coil side
of the outdoor unit must be a minimum of 6” from
any wall or surrounding shrubbery to ensure adequate airflow.
Important:
When installing multiple units, ensure the discharge air
from one unit is not drawn into another unit. When
installing single or multiple units in an alcove, roof well,
or partially enclosed area, ensure there is adequate
ventilation to prevent recirculation of discharge air.
Important:
If installation is in areas with known prevailing winds in
excess of 25 mph, a wind baffle kit is suggested.
Min 36”
Unrestricted
Min. 6” to
Solid Structure
Airflow
Direction
Note: 2’ Required
for Service Panel
Access
Service
Panel
Min. 6”
clearance to
obstruction
(Coil Side)
Airflow
Direction
Min. 36” clearance
to obstruction
(Fan Side)
Voltage
hook-up