5
CVHE-SVN01C-EN
General Information
About this Manual
This manual describes proper
installation of Model CVHE, CVHF,
and CVHG 50 Hz and 60 Hz chillers
with the Tracer CH530 Controls
platform. See Figure 1 for an
illustration of a Centrifugal Chiller
with the Tracer CH530 Unit
Control Panel.
These chillers are equipped with
microcomputer-based control
systems whether standard cooling
or heat-recovery. A careful review of
this information along with the
submittal package provided for the
unit will assure that the chiller is
correctly installed.
Product Description Block
Trane 50 Hz and 60 Hz hermetic
CenTraVac units are defined by the
product definition and selection
system (PDS). Each unit is defined by
the product description block which
appears on the unit nameplate. A
service model number which
represents the unit as-built is
provided on the unit nameplate,
along with a specific unit service
number. Both these are utilized
whenever parts or service are
required. An example is provided in
the unit operation and maintenance
manual (CVHE-SVU01A-EN).
Commonly Used Acronyms
AFD = Adjustable Frequency Drive
ASME = American Society of
Mechanical Engineers
ASHRAE = American Society of
Heating, Refrigerating and Air
Conditioning Engineers
BAS = Building Automation System
LBU = La Crosse Business Unit
CABS = Auxiliary Condenser Tube-
Bundle Size
CDBS = Condenser Bundle Size
CESZ = Condenser Shell Size
CWR = Chilled Water Reset
DTFL = Delta-T at Full Load (i.e., the
difference between entering and
leaving chilled water temperatures at
design load)
EVBS = Evaporator Size
EVSZ = Evaporator Shell Size
FC = Free Cooling
GPM = Gallons-per-Minute
HGBP = Hot Gas Bypass
HVAC = Heating, Ventilating and Air
Conditioning
IE = Internally Enhanced Tubes
IPC = Interprocessor Communication
PFCC = Power Factor Correction
Capacitor
PSID = Pounds-per-Square-Inch
Differential
UCP = Chiller Control Panel
CH530 = Tracer CH530 Platform Unit
Control Panel
Unit Nameplate
The unit nameplate is located on the
left side of the unit control panel
(UCP). The following information is
provided on the unit nameplate.
1. Unit model and size descriptor
2. Unit serial number
3. Identifies unit electrical
requirements
4. Lists correct operating charge and
type of refrigerant
5. Lists unit test pressures and
maximum operating pressures
6. Identifies unit installation,
operation and maintenance
manuals
7. Product description block
Metric Conversion
For tables and charts in this manual,
the following conversions apply:
In. × 2.54 = cm
Ft. × 30.48 = cm
Lbs. × .453 = kg