BAYSTAT253A HUMIDITY CONTROL

69-1698

4

Pub.No.: 22-5203-01

HEATING CYCLE HUMIDITY 

CONTROL ADJUSTMENTS

Humidity Control Adjustment

To maintain optimum humidity control without causing 
condensation on cold surfaces such as windows, the 
homeowner must adjust the setpoint as the outdoor 
temperature changes.

To reduce relative humidity, reduce the setpoint 
approximately 3% RH humidity every 24 hours. To 
increase relative humidity, increase the setpoint 
approximately 3% RH  every 24 hours.

Setpoint Adjustment

Set the humidity setpoint according to the prevailing 
outdoor temperature. See Table 1 for recommended 
settings.

Table 1. Recommended Humidity Control Setting.

Outdoor Temperature

Recommended 

Humidity Control 

Setting

°F

°C

-20

-29

15

-10

-23

20

0

-18

25

+10

-12

30

+20

-7

35

>+20

>-7

40

Содержание BAYSTAT253A

Страница 1: ...to your thermostat See Fig 2 However the humidity control can be mounted in any other convenient location in the living area or equipment room NOTE The humidity control electrical connections are not...

Страница 2: ...l case IMPORTANT Use 18 to 22 gauge wire for correct wiring Fig 4 Positioning return air duct template M19830 THERMOSTAT WALLPLATE MOUNTING TEMPLATE MOUNTING HOLES 2 WIRING HOLES FOR MOUNTING ON RIGHT...

Страница 3: ...ram for system with 2 speed fan motor Fig 7 Typical wiring diagram of current sensing relay with humidifier Fig 8 Typical wiring diagram of sail switch with humidifier Fig 9 Typical wiring diagram for...

Страница 4: ...mperature changes To reduce relative humidity reduce the setpoint approximately 3 RH humidity every 24 hours To increase relative humidity increase the setpoint approximately 3 RH every 24 hours Setpo...

Страница 5: ...air Fig 10 Wiring for variable speed air handler 5 6 SUPPL HTR CONTROL BOX 8 3 7 2 1 LOW VOLTAGE WIRING TO BE NO 18 A W G MINIMUM CONDUCTOR 2 WHEN HEATERS ARE USED DISCARD POWER LEADS WITH POLARIZED...

Страница 6: ...MON TERMINAL 7 THE Y TERMINAL FROM THE THERMOSTAT MST BE WIRED TO THE Y TERMINAL OF THE FURNACE CONTROL FOR PROPER BLOWER OPERATION DURING COOLING 2 LOW VOLTAGE 24 V WIRING TO BE NO 18 A W G MINIMUM 3...

Страница 7: ...BAYSTAT253A HUMIDITY CONTROL 7 69 1698 Pub No 22 5203 01...

Страница 8: ...69 1698 G H 11 03 For more information contact your local Dealer Distributor BAYSTAT253A HUMIDITY CONTROL Pub No 22 5203 01 American Standard Inc 6200 Troup Highway Tyler TX 75711 9010...

Отзывы: