background image

® U.S. Registered Trademark
Copyright © 2003  •  All Rights Reserved 

INSTALLER’S GUIDE

69-1698

 BAYSTAT253A

Humidity Control

APPLICATION

The humidity control provides automatic low voltage 
control of humidifiers in central heating and cooling 
equipment for both humidification and dehumidification 
applications. See Fig. 1. It has an spst, snap-acting, 
dust-proof switch that opens when humidity rises above 
the control setting. It is designed for wall or surface duct 
mounting.

INSTALLATION

When Installing this Product...

1.

Read these instructions carefully. Failure to follow 
them could damage the product or cause a haz-
ardous condition.

2.

Check the ratings given in the instructions and on 
the product to make sure the product is suitable 
for your application.

3.

Installer must be a trained, experienced service 
technician.

4.

After installation is complete, check out product 
operation as provided in these instructions.

CAUTION

Personal Injury Hazard.
Power supply can cause electrical shock.

Disconnect power supply before beginning 
installation. 

Location and Mounting

A mounting template is included for mounting the 
humidity control next to your thermostat. See Fig. 2. 
However, the humidity control can be mounted in any 
other convenient location in the living area or equipment 
room.

NOTE: The humidity control electrical connections are 

not shared with the thermostat.

Fig. 1. Humidity control.

Wall Mounting

IMPORTANT

Mount the control in an area with average 
room temperature and average relative 
humidity.

Select a location for mounting the humidity control:

1.

Hold the mounting template (included) next to 
your thermostat. Select the mounting side for the 
humidity control. The template is reversible for 
mounting on either the left or right side of the 
humidity control. See Fig. 2.

2.

Mark the holes for the two mounting screws 
(included). Then mark the hole for the low voltage 
wiring on the template that corresponds with the 
side selected in step 1. 

3.

Remove the template and drill the holes.

4.

Run low voltage wiring to the location and pull 
about 6 in. (152 mm) of wire through the hole.

5.

Plug hole with nonflammable insulation to prevent 
drafts from affecting the control operation.

6.

Remove the humidity control case from the base. 
See Fig. 1.

7.

Position the base on the wall with the arrow up.

8.

Use the two in. (25 mm) mounting screws to 
secure the base to the wall.

M19845

CASE REMOVAL 
SLOT

HOLE FOR WIRING 
THE DUCT MOUNTING 
INSTALLATIONS

Humidity Control

   
 

    

Pub. No.: 22-5203-01

Содержание BAYSTAT253A

Страница 1: ...to your thermostat See Fig 2 However the humidity control can be mounted in any other convenient location in the living area or equipment room NOTE The humidity control electrical connections are not...

Страница 2: ...l case IMPORTANT Use 18 to 22 gauge wire for correct wiring Fig 4 Positioning return air duct template M19830 THERMOSTAT WALLPLATE MOUNTING TEMPLATE MOUNTING HOLES 2 WIRING HOLES FOR MOUNTING ON RIGHT...

Страница 3: ...ram for system with 2 speed fan motor Fig 7 Typical wiring diagram of current sensing relay with humidifier Fig 8 Typical wiring diagram of sail switch with humidifier Fig 9 Typical wiring diagram for...

Страница 4: ...mperature changes To reduce relative humidity reduce the setpoint approximately 3 RH humidity every 24 hours To increase relative humidity increase the setpoint approximately 3 RH every 24 hours Setpo...

Страница 5: ...air Fig 10 Wiring for variable speed air handler 5 6 SUPPL HTR CONTROL BOX 8 3 7 2 1 LOW VOLTAGE WIRING TO BE NO 18 A W G MINIMUM CONDUCTOR 2 WHEN HEATERS ARE USED DISCARD POWER LEADS WITH POLARIZED...

Страница 6: ...MON TERMINAL 7 THE Y TERMINAL FROM THE THERMOSTAT MST BE WIRED TO THE Y TERMINAL OF THE FURNACE CONTROL FOR PROPER BLOWER OPERATION DURING COOLING 2 LOW VOLTAGE 24 V WIRING TO BE NO 18 A W G MINIMUM 3...

Страница 7: ...BAYSTAT253A HUMIDITY CONTROL 7 69 1698 Pub No 22 5203 01...

Страница 8: ...69 1698 G H 11 03 For more information contact your local Dealer Distributor BAYSTAT253A HUMIDITY CONTROL Pub No 22 5203 01 American Standard Inc 6200 Troup Highway Tyler TX 75711 9010...

Отзывы: