Warnings and Cautions

MS-SVN047B-EN

Warnings and Cautions 

Warnings and Cautions.

Notice that warnings and 

cautions appear at appropriate intervals throughout this 
manual. Warnings are provided to alert installing 
contractors to potential hazards that could result in 
personal injury or death, while cautions are designed to 
alert personnel to conditions that could result in 
equipment damage. 

Your personal safety and the proper operation of this 
machine depends upon the strict observance of these 
precautions.

Read this manual thoroughly before operating or giving 
service to this unit. 

I

¡

Important!

Environmental Concerns - 

Scientific research has 

shown that certain man-made chemicals can affect the 
earths naturally occurring stratospheric ozone layer when 
released to the atmosphere. In particular, several of the 
identified chemicals that may affect the ozone layer are 
refrigerants that contain Chlorine, Fluorine and Carbon 
(HCFCs). Not all refrigerants containing these compounds 
have the same potential impact to the environment. Trans 
advocates the responsible handling of all refrigerants - 
including industry replacements for CFCs such as HCFCs 
and HFCs. 

Responsible Refrigerant Practices -

 Trane believes 

that responsible refrigerant practices are important to the 
environment, our customers and the air-conditioning 
industry. All technicians who handle refrigerants must be 
certified. The Federal Clean Air Act (Section 608) sets forth 
the requirements for handling, reclaiming, recovering and 
recycling of certain refrigerants and the equipment that is 
used in these service procedures. In addition, some states 
or municipalities may have additional requirements that 
must also be adhered to for responsible management of 
refrigerants. Know the applicable laws and follow them. 

ATTENTION:

 

Warnings and Cautions appear at appropriate 

sections throughout this literature. Read these carefully:

WARNING

Indicates a potentially hazardous 
situation which, if not avoided, could 
result in death or serious injury.

CAUTION

s

Indicates a potentially hazardous 
situation which, if not avoided, could 
result in minor or moderate injury. It 
may also be used to alert against 
unsafe practices.

NOTICE: 

Indicates a situation that could result 
in equipment or property damage 
only accidents.

WARNING

Ground Required!

Follow proper local electrical code on requirements for 
grounding. Failure to follow code could result in death 
of serious injury.

WARNING

R410A Refrigerant under Higher Pressure 
than R22!

The units described in this manual use R410A 
refrigerant which operates at 50 to 70% higher 
pressures than R-22. Use only R-410A approved service 
equipment. Refrigerant cylinders are painted with 
“pink” color to indicate the type of refrigerant and may 
contain a “dip” tube to allow for charging of liquid 
refrigerant into the system. For specific handling 
concerns with R-410A, contact your local Trane 
representative.

Failure to use R-410A approved service equipment 
could result in standard equipment exploding under R-
410A higher pressure which could result in death or 
serious injury.

WARNING

This information is intended for use by individuals 
possessing adequate backgrounds of electrical and 
mechanical experience. Any attempt to repair a central 
air conditioning product may result in death, personal 
injury or property damage. The manufacturer or seller 
cannot be responsible for the interpretation of this 
information, no can it assume any liability in 
connection with its use.

NOTICE

Use PVE Oil with R-410A Mini-Split units!

All R-410A mini-splits use a PVE oil (Polyvinyl Ether Oil) 
that readily absorbs moisture from the atmosphere. To 
limit this “hygroscopic” action, the system should 
remain sealed whenever possible. If a system has been 
open to the atmosphere for more that 4 hours, the 
compressor oil must be replaced. Never break a 
vacuum with air and always change the driers when 
opening the system for component replacement. For 
specific handling concerns with PVE oil, contact your 
local Trane representative. 

USE ONLY THE FACTORY RECOMMENDED - DAFNE 
HERMETIC OIL FV50S - for servicing these units. 

Failure to follow these recommendations could result in 
equipment damage. 

Содержание 4MXW5

Страница 1: ...stalled adjusted or altered equipment by an unqualified person could result in death or serious injury When working on the equipment observe all precautions in the literature and on the tags stickers...

Страница 2: ......

Страница 3: ...in death or serious injury CAUTIONs Indicates a potentially hazardous situation which if not avoided could result in minor or moderate injury It may also be used to alert against unsafe practices NOTI...

Страница 4: ...General Information 5 Accessories 6 Typical Installation 7 Installation Location 8 Indoor Unit Outdoor Unit 9 Vacuum Pump and Leak Inspection 13 Outdoor Condensation Drainage heat pump only 14 Connec...

Страница 5: ...n On arrival inspect the unit before signing the delivery note Specify any damage on the unit on the delivery note and send a registered letter of protest to the last carrier of the goods within 71 ho...

Страница 6: ...6 MS SVN047B EN Accessories Accessories Figure 1 Accessories for Installation 0 10...

Страница 7: ...MS SVN047B EN 7 Installation Installation Figure 2 Names and functions of each part...

Страница 8: ...air filters can be easily removed Outdoor Unit WARNING Adequate Support Wall structure must be adequate to support the weight of the unit Failure to ensure adequate structural support could result in...

Страница 9: ...irections shown as follows Figure 4 Piping directions Drill a 65mm diameter hole in the wall if the units is up to 18MBH or a 95mm diameter hole if the unit is up to above 18MBH The perforation should...

Страница 10: ...See figure below 3 The entire length of the indoor drain hose should be wrapped around with insulation Figure 6 Drain Hose Hanging the Unit on the Wall 1 While directing piping and wiring either from...

Страница 11: ...asten the flared nut manually and then tighten the nut using a spanner wrench or a torque wrench Table 1 Tightening torque Note First connect the connection pipe to the indoor unit then connect to the...

Страница 12: ...t and attach power wiring cord to terminal block Wiring should match that of the indoor unit 3 Using a wire clamp attach the power wiring cord inside the control panel for cooling and heating unit use...

Страница 13: ...6 If vacuum gauge does not rise above 500 microns in one 1 minute the evacuation should be complete 7 Blank off vacuum pump and micron gauge and close vales on manifold gauge set Note DO NOT VENT REFR...

Страница 14: ...gerant flow If refrigerant lines are longer than fifteen feet 8m it will be necessary to adjust system refrigerant charge upon completion of installation Outdoor Condensation Drainage Heat Pump type o...

Страница 15: ...ant leak test It may cause insufficient cooling heating capacity Is thermal insulation sufficient It may cause condensation and dripping Does the unit drain appropriately It may cause condensation and...

Страница 16: ...mm 6 1 4 6 1 4 6 1 4 6 1 4 Gas pipe mm 9 52 3 8 9 52 3 8 12 1 2 12 1 2 Maximum Distance Height m 15 15 20 20 Length m 30 30 40 40 Standard Efficiency 60hz Cooling Only 4MYW5509A1 4TYK5509A1 4MYW5512A...

Страница 17: ...4TXK5512AB 4MXW5518AB 4TXK5518AB 4MXW5524AB 4TXK5524AB Refrigerant Charge kg R410A 0 70 R410A 0 96 R410A 1 25 R410A 1 40 Length m 5 5 5 5 Additional Gas Charge g m 15 15 20 20 Outside Diameter Liq pip...

Страница 18: ...re Hazards with Improperly Installed and Grounded Field Wiring Improperly installed and grounded field wiring poses fire and electrocution hazards To avoid these hazards you must follow requirements f...

Страница 19: ...9 325 725 8 1 7 1 0 287 225 81 7 3 3 1 02725 0 3 63 63 20 287 1 6 1 02725 1 0 1 7 5 1 78 1 1 1 208 8 3 0DLQ RDUG 1 1 6 7 2 0 62 7 21 75 RPS DQG 7 7 1 1 1 02725 0 2 1 5 3527 725 29 5 2 5 29 203 8 9 8...

Страница 20: ...ZKHQ WKH YROWDJH RI WHUPLQDO 3 DQG 1 DW 3 LV KLJKHU WKDQ 9 WR SUHYHQW WKH ULVN RI HOHFWULFDO VKRFN 0 5 1 5 1 0 5 725 3 7 50 1 2 2 7 50 1 7 3 9 9 9 9 97 97 5 32 5 3 RDUG 3 LOWHU 1 8 1 1 1 8 2 7 50 1 1...

Страница 21: ...MS SVN047B EN 21 Wiring Diagrams Figure 18 4TYK4518A1 4TXK5524A1 Outdoor Unit Heat Pump Figure 19 4MXW5509AB 4MXW5512AB Indoor Unit Heat Pump...

Страница 22: ...22 MS SVN047B EN Wiring Diagrams Figure 20 4MXW5518AB 4MXW5524AB Indoor Unit Heat Pump Figure 21 4TXK5509AB Outdoor Unit Heat Pump...

Страница 23: ...MS SVN047B EN 23 Wiring Diagrams Figure 22 4TXK5512AB Outdoor Unit Heat Pump Figure 23 4TXK5512AB 4TXK5524AB Outdoor Unit Heat Pump...

Страница 24: ...bles and increase industrial productivity and efficiency We are a global business of 13 million committed to a world of sustainable progress and enduring results Trane has a policy of continuous produ...

Отзывы: