6200 Troup Highway
Tyler, TX 75707-9010

10/14  
The manufacturer has a policy of continuous product and product data improvement and it reserves the right 
to change design and specifications without notice.

General
All units shall be factory assembled, 
piped, internally wired and fully charged 
with refrigerant. All units shall be de-
signed to operate at outdoor ambient 
temperatures as high as 115°F.  Cooling 
capacities shall be rated in accordance 
with A.H.R.I. standards. The 4DCY4 heat-
ing/cooling unit design is certified to UL 
Standards 1995 and ANSI 221.47/CSA 
2.3, specifically for outdoor applications 
using natural gas or propane

All units 

shall be designed for outdoor rooftop or 
ground level installation. Unit casing is 
constructed of heavy gauge, galvanized 
steel and painted with a weather-resistant 
powder paint. 
Shipped for horizontal application,  
convertible to downflow.
Casings
All panels shall be heavy gauge steel, 
gasketed and insulated. Foil-faced 
insulation shall be in the heat exchanger 
section. Foil-faced insulation shall be in 
the evaporator section. Base pan shall be 
heavy gauge steel.

 WEATHERGUARD™ 

exterior corrosion resistant screws shall 
be used for added resistance to rust and 
corrosion.
Controls
Refrigeration cycle controls shall include 
condenser fan, evaporator fan and com-
pressor contactors. Compressors shall 
be equipped with a combination internal 
winding thermostat/current overload. 
Internal high pressure relief shall also be 
provided.
 
Refrigeration System
Compressors — 
The 

Climatuff

®

 compressor features in-

ternal over temperature and pressure pro-
tector, total dipped hermetic motor. Other 
features include: centrifugal oil pump, and 
low vibration and noise. 
Evaporator Coil — Internally enhanced 
3/8-inch OD seamless copper tubing 
me chani cally bonded to aluminum fins, 
factory pressure and leak tested at 250 
to 300 psig. All units have TXV to control 
refrigeration flow.

Condenser Coil — 
The 

Spine Fin™ condenser coil shall be 

continuously wrapped, corrosion resistant 
all aluminum with minimum brazed joints. 
This coil is 3/8 inch OD seamless alumi-
num tubing glued to a continuous alumi-
num fin. Coils are lab tested to withstand 
2,000 pounds of pressure per square 
inch. The outdoor coil provides low airflow 
resistance and efficient heat transfer. 
The coil is protected on all four sides by 
louvered panels.
Indoor Air Fan — Direct-drive, forward-
curved, centrifugal wheel in a Composite 
Vortica

®

  Blower  housing. Motor shall 

have thermal overload protection. Perma-
nently lubricated motor bearings. Motor/
blower assembly isolated from unit with 
rubber mounts.
Condenser Fan — Direct-drive, draw 
through propeller type. Weather-proofed 
permanent split capacitor fan motor shall 
have built-in thermal overload and perma-
nently lubricated motor bearings.
Low Ambient — Standard refrigerant 
system operation down to 55°F. Low am-
bient accessory required for operation to 
0°F ambient condition.

Gas-Fired Heating System — Models 
shall provide completely assembled, 
wired and piped gas fired heating systems 
within unit. Threaded gas connection on 
the unit.
Electronic Ignition System — Main 
burner is lit each time thermostat calls for 
gas heat. Flame sensor proves flame and 
keeps the main burners on. Should a loss 
of flame occur, the main valve closes and 
the spark recurs within 0.8 second. When 
thermostat is satisfied, main burner is 
extinguished.
Forced Combustion Blower — Insures 
flame stability under varying wind condi-
tions. Gives higher combustion efficiency 
and location flexibility.

Heat Exchanger — stainless steel 
tubes. Free floating design.
Burners —  Stainless  steel. Multi-port 
inshot.
Accessories  
(U.S. Domestic Models)
Roof Curb — 
The roof curb shall 
be designed to mate with the unit 
and provide support and complete 
weather-tight installation when properly 
installed. Curb shall ship knocked down 
for field assembly, and include wood 
nailer strips.

Modulating Economizer — This 
accessory shall be field installed and 
be composed of the following items: 
0-100% fresh air damper, damper 
drive motor fixed dry bulb enthalpy 
control, and low voltage polarized plug 
for electrical connections. Solid state 
enthalpy or  differential enthalpy control 
is optional. Economizer operations shall 
be controlled by the preset position 
of the enthalpy control. A barometic 
relief damper shall be standard with 
the economizer and provide a pressure 
operated damper that shall be gravity 
closing and prohibit entrance of outside 
air on equipment “off” cycle.
Manual Fresh Air Hood
Manual outside air provides a fixed out-
side air quantity from 0 to 25 percent. 
Includes hood and birdscreen.
Low Ambient Control
Control allows cycling of compressor 
under low ambient cooling conditions. 
Required for cooling operation to 0°F.
Propane Gas
Conversion Kit — 
For conversion from 
natural gas to LP gas.

Mechanical Specifications

Содержание 4DCY4024

Страница 1: ... 2014Trane Pub No 22 1799 20 EN Product Data 4DCY4024 through 4DCY4060 Packaged Convertible Dual Fuel 14 SEER 2 5 Ton 60 120 MBTU R 410A 22 1799 20 EN ...

Страница 2: ... these products including the compressor have been designed and manufactured for maximum service Every Climatuff compressor is designed and manufac tured to exacting specifications Each design is life tested in extreme envi ronments to ensure reliable and long lasting operation in normal applications Each compressor has internal motor protection for added reliability Single Packaged Convertible Du...

Страница 3: ...3 Contents Optional Equipment Listing 4 General Data 5 Indoor Blower Performance 8 TypicalWiring 16 Optional Equipment 14 Dimensional Data 19 Mechanical Specifications 25 ...

Страница 4: ...BAYFLTR201B Head Pressure Control Low Ambient Cool 208 240v Kit 5 BAYLOAM105A Quick Start Kit 4DCY4 1 BAYQSKT300A Crankcase Heater Recip 4DCY4024 30 230v 5 BAYCCHT101A Crankcase Heater Scroll 4DCY4042 48 60 230v 5 BAYCCHT102A Crankcase Heater Scroll 4DCY4036 230v 5 BAYCCHT103A Adapter Curb 4DCY4024 36 to BAYCURB030 38 BAYADAP050A Adapter Curb 4DCY4024 36 to BAYCURB033 BAYADAP051A Adapter Curb 4DCY...

Страница 5: ...60 1 0 1 7 CENTRIFUGAL 10 X 10 DIRECT VARIABLE SEE FAN PERFORMANCE TABLE 1 2 VARIABLE 208 230 1 60 4 3 4 3 CENTRIFUGAL DIRECT 2 1 20 3350 2600 208 230 1 60 0 34 NO THROWAWAY 4 R410A 6 56 H X W X L 45 86 44 5 52 03 481 385 MODEL RATED Volts PH Hz Performance Cooling BTUH Indoor Airflow CFM Power Input KW EER SEER BTU Watt Hr Sound Power Rating dB A 7 HP Heating Performance High Temp BTUH COP Power ...

Страница 6: ...rive No Speeds Motor HP R P M High Low Volts Ph Hz FLA FILTER FURNISHED Type Recommended Recmd Face Area sq ft REFRIGERANT Charge lbs DIMENSIONS Crated in WEIGHT Shipping Net lbs 4DCY4048C1090B 208 230 1 60 47500 1470 3 96 12 0 14 0 73 45000 3 5 3 77 26800 2 3 3 44 8 0 90000 72900 30 60 72000 58320 81 NATURAL LP 1 2 208 230 1 60 33 9 50 50 SCROLL 208 230 1 60 20 5 109 SPINE FIN 2 24 18 01 3 8 EXPA...

Страница 7: ...Drive No Speeds Motor HP R P M High Low Volts Ph Hz FLA FILTER FURNISHED Type Recommended Recmd Face Area sq ft REFRIGERANT Charge lbs DIMENSIONS Crated in WEIGHT Shipping Net lbs 4DCY4048A3096C 208 230 3 60 47000 1470 4 03 10 85 14 0 73 42500 3 5 3 56 26800 2 3 3 44 8 0 96000 77500 30 60 72000 62000 80 NATURAL 1 2 208 230 3 60 25 3 35 35 SCROLL 208 230 3 60 13 7 83 1 SPINE FIN 2 24 18 01 3 8 EXPA...

Страница 8: ...925 7 ON 8 ON D 700 975 4DCY4024 Switch Settings Nominal Airflow Auxiliary Heating Airflow horizontal or downflow from 2 to 6 wg 4DCY4030 HOR DIPSWITCH SETTINGS External Static Pressure in wg AIRFLOW SETTING 1 2 3 4 0 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 0 350 CFM TON OFF OFF OFF ON Watts 112 155 176 199 231 270 299 289 197 CFM 867 905 904 899 904 914 907 840 650 400 CFM TON OFF OFF OFF OFF Wat...

Страница 9: ...4DCY4036 Switch Settings Nominal Airflow Auxiliary Heating Airflow horizontal or downflow from 2 to 6 wg 4DCY4042A HOR DIPSWITCH SETTINGS External Static Pressure in wg AIRFLOW SETTING 1 2 3 4 0 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 0 350 CFM TON OFF OFF OFF ON Watts 160 185 214 245 277 308 339 368 396 423 CFM 1206 1211 1213 1215 1215 1214 1212 1208 1201 1190 400 CFM TON OFF OFF OFF OFF Watts 23...

Страница 10: ...1817 1818 1820 1819 1817 1820 1815 1810 Selection Low Stage High Stage 7 OFF 8 OFF A 1075 1375 7 ON 8 OFF B 1100 1450 7 OFF 8 ON C 1150 1500 7 ON 8 ON D 1200 1575 Switch Settings Nominal Airflow 4DCY4048C 090 can be 1 or 3 Indoor Fan Performance 4DCY4060 Down Airflow Horizontal Airflow Low Stage High Stage 7 OFF 8 OFF A 1375 1800 7 ON 8 OFF B 1450 1900 7 OFF 8 ON C 1525 1975 7 ON 8 ON D 1575 2075 ...

Страница 11: ...11 Typical Field Wiring ...

Страница 12: ...12 Typical Wiring ...

Страница 13: ...13 Typical Wiring ...

Страница 14: ...s page are prepared by the manufacturer in order to provide detail regarding job layout only These drawings are not intended to be used as a basis to construct build or modify the items depicted in the drawings The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use ...

Страница 15: ...s page are prepared by the manufacturer in order to provide detail regarding job layout only These drawings are not intended to be used as a basis to construct build or modify the items depicted in the drawings The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use ...

Страница 16: ...is to construct build or modify the items depicted in the drawings The manufacturer is not respon sible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use BAYFLTR101 201B 1 2 Filter Rack Mounts in Filter Coil Section BAYACCDOR1A BAYACCDOR2A Hinged Filter Access Door Replaces Filter Coil Access Panel Filter ...

Страница 17: ...d by the manu facturer in order to provide detail regarding job layout only These drawings are not intended to be used as a basis to construct build or modify the items depicted in the drawings The manu facturer is not responsible for the unauthorized use of these drawings and ex pressly disclaims any liability for damages resulting from such unauthorized use Mixed Air Sensor Economizer Unit Appli...

Страница 18: ... not responsible for the unauthorized use of these drawings and expressly disclaims any liability for dam ages resulting from such unauthorized use D C B A E Manual Fresh Air Model Unit Application Models A B C D BAYOSAH001 4YC WC3018 036 4TC 3018 036 4W T Y DCY4024 036 4W Y DCZ6036 22 7 16 20 11 16 12 3 8 9 3 16 BAYOSAH002 4YC WC3042 060 4TC 3042 060 4W T Y DCY4042 060 4W Y DCZ6048 060 25 3 16 20...

Страница 19: ...19 Dimensional Data 4DCY4024 through 4DCY4036 1 of 3 ...

Страница 20: ...20 Dimensional Data 4DCY4024 through 4DCY4036 2 of 3 ...

Страница 21: ...21 Dimensional Data 4DCY4024 through 4DCY4036 3 of 3 ...

Страница 22: ...22 4DCY4042 through 4DCY4060 1 of 3 Dimensional Data ...

Страница 23: ...23 Dimensional Data 4DCY4042 through 4DCY4060 2 of 3 ...

Страница 24: ...24 4DCY4042 through 4DCY4060 3 of 3 Dimensional Data ...

Страница 25: ...d on all four sides by louvered panels Indoor Air Fan Direct drive forward curved centrifugal wheel in a Composite Vortica Blower housing Motor shall have thermal overload protection Perma nently lubricated motor bearings Motor blower assembly isolated from unit with rubber mounts Condenser Fan Direct drive draw through propeller type Weather proofed permanent split capacitor fan motor shall have ...

Отзывы: