Installer’s Guide

CHECKOUT PROCEDURE

After installation has been completed, it is recommended that the entire system be checked against the following list:

1. Refrigerant Line, Leak checked .................................. [

]

2. Suction Lines and Fittings properly insulated ........... [

]

3. Have all Refrigerant Lines been secured and

isolated properly? ........................................................ [

]

4. Have passages through masonry been sealed?

If mortar is used, prevent mortar from coming
into direct contact with copper tubing ........................ [

]

5. Verify tightness of all electrical connects ................... [

]

6. Observe outdoor fan during on cycle for clearance

and smooth operation ................................................. [

]

7. Indoor coil drain line drains freely. Pour water

into drain pan .............................................................. [

]

8. Supply registers and return grilles open and

unobstructed ............................................................... [

]

9. Return air filter installed ............................................ [

]

10. Thermostat thermometer is accurate. Check

against a reliable thermometer. Adjust per
instructions with thermostat ...................................... [

]

11. Is correct speed tap being used?

(Indoor blower motor) ................................................. [

]

12. Operate complete system in each mode to

insure safe operation. .................................................. [

]

SYSTEM FAULTS

REFRIGERANT CIRCUIT

Head Pressure Too High

Head Pressure Too Low

Suction Pressure Too High

Suction Pressure Too Low

Liquid Refrig. Floodback (TXV)

Liquid Refrig. Floodback
(Cap. Tube)

I.D. Coil Frosting

Compressor Runs
Inadequate or No Cooling/Htg

ELECTRICAL

Compressor & O.D. Fan
Won’t Start

Compressor Will Not Start
But O.D. Fan Runs

O.D. Fan Won’t Start

Compressor Hums But Won’t Start

Compressor Cycles on IOL

I.D. Blower Won’t Start

DEFROST

Unit Won’t Initiate Defrost

Defrost Terminates on Time

Unit Icing Up

WHA

TO

 CHECK MODE

PO

WER SUPPL

Y

HIGH V

O

LTA

GE 

WIRING

COMPRESSOR IOL

RUN CAP

AC

IT

OR

ST

AR

T CAP

AC

IT

OR

ST

AR

T RELA

Y

CONT

AC

TOR CONT

ACTS

LO

W V

O

LTA

GE 

WIRING

CONTR

OL TRANSFORMER

THERMOST

AT

CONT

AC

TOR COIL

LO

W V

O

LTA

GE 

FUSE

STUCK COMPRESSOR

INEFFICIENT COMP

.

REF

. UNDERCHARGE

REF

. O

VERCHARGE

EXCESSIVE EV

AP

. LO

AD

NONCONDENSABLES

RES

. O

.D

. AIRFLO

W

O

.D

. AIR RECIRCULA

TION

TXV STUCK OPEN

SUPERHEA

T

RES

. I.D

. AIRFLO

W

REF

. CIR.

 RESTRICTIONS

SO

V LEAKING

SO

V COIL DEFECTIVE

CHECK V

AL

VE 

LEAKING

*

DEFR

OST RELA

Y DEF

.

DEFR

OST CONTR

OL DEF

.

C
H
C
H
C
H
C
H
C
H
C
H
C
H
C
H

C
H
C
H
C
H
C
H
C
H
C
H

C
H
C
H
C
H

P
P

P
P

P
P
P
P
P
P

P
P
P
P

S
S

S
S

S
S

S
S
S
S

S
S

S
S
S
S

S
S
S
S
S
S
S
S

S
S

S
S

P
P

P
P

S
S

S
S

P
P

P
P

S
S

P
P

P
P
P
P

P
P
P
P
P
P
P
P

S
S
S
S

S
S

S
S

P
P

P
P

P

P
P

P
P

P

P

P
P

P

P
P

P
P

P
P

P

S

S
S

S
S

S
S

P

S

S
S
S

S
S

S

S

S

S
S
S

S

S

S
S

P
P

S
S
S
S
S
S

S
S

S
S

S
S

P

P

P

P
P

P

S

S
S
S
S

S
S

S
S

S
S
P
P

S
S

S
S

S

S

S

S

P

P

P
P
P

P
P

S
S

P

P

P

P

C - Cooling     H - Heating     P - Primary Causes     S - Secondary Causes    

*

 - 3 Phase Only

TROUBLESHOOTING CHART — WHAT TO CHECK

2TWR2-IN-1B

SV-UN-S/SP-2TWR2-IN-1B

2TWR2-IN-1A

PI Louisville & Webb/Mason-Houston

Содержание 2TWR1

Страница 1: ...red sufficiently for the purchaser s purposes the matter should be referred to your installing dealer or local distributor A GENERAL The following instructions cover 2TWR1 and 2TWR2 Heat Pump Units NO...

Страница 2: ...are brazed not soldered Condensing units have provisions for braze connections Pressure taps are provided on the service valves of outdoor unit for compressor suction and liquid pressures The indoor...

Страница 3: ...zing It is recommended that the pressure tap port valve core be removed and a wet rag wrapped around the valve body NOTE Use care to make sure that no moisture enters pressure tap port while wet rag i...

Страница 4: ...e upon completion of installation See unit Service Facts F ELECTRICAL CONNECTIONS WARNING When installing or servicing this equipment ALWAYS exercise basic safety precautions to avoid the possibility...

Страница 5: ...r sump heat where used Do not change the Thermostat System Switch until power has been applied for one 1 hour Following this procedure will prevent potential compressor overload trip at the initial st...

Страница 6: ...4 829 32 5 8 756 29 3 4 1 1 8 3 8 137 5 3 8 86 3 3 8 210 8 1 4 79 3 1 8 508 20 2TWR1060A 4 1 841 33 1 8 946 37 1 4 870 34 1 4 1 1 8 3 8 152 6 98 3 7 8 219 8 5 8 86 3 3 8 508 20 2TWR2018A 2 2 651 25 5...

Страница 7: ...18 BC51D2 3 7 Installer s Guide MOUNTING HOLE LOCATION Note All dimensions are in MM Inches NOTE For model base size see table on page 6 From Dwg 21D152637 Rev 1...

Страница 8: ...ompressor O D Fan Won t Start Compressor Will Not Start But O D Fan Runs O D Fan Won t Start Compressor Hums But Won t Start Compressor Cycles on IOL I D Blower Won t Start DEFROST Unit Won t Initiate...

Отзывы: