10
18-HD64D1-4
Pressing the “Standard” button allows manual selection and configuration of basic equipment components.
NOTE: In a communicating system, components will be discovered automatically, manual setup is not required.
Menu
Setting
Available Options
5.2.1 STANDARD
Outdoor Unit Type ............................................................................ None
Cooling Only
Heat Pump
Outdoor Unit Stages ........................................................................ 1
2
Compressor Type ............................................................................. Single Compressor Two Stage
Two Compressor Two Stage
Indoor Unit Type ............................................................................... Electric
Gas/Oil
Hydronic
Indoor Unit Heat Stages .................................................................. None
1
2
3
Modulating
Indoor Unit Blower Type ................................................................... Variable Speed
Non-Variable Speed
Zoning .............................................................................................. Enable
Disable
The “Advanced” settings are used to fine-tune the operation of the 950 Control. Installed accessories can also be
configured in “Advanced” Settings.
5.2.2 ADVANCED
EQUIPMENT
Compressor Cooling Cycles Per Hour ............................................. 2, 3, 4, 5 or 6
1st Stage Compressor Heating Cycles Per Hour ............................. 2, 3, 4, 5 or 6
2nd Stage Compressor Heating Cycles Per Hour ........................... 2, 3, 4, 5 or 6
Compressor Heating Cycles Per Hour ............................................. 2, 3, 4, 5 or 6
1st Stage Compressor Cooling Cycles Per Hour ............................. 2, 3, 4, 5 or 6
2nd Stage Compressor Cooling Cycles Per Hour ............................ 2, 3, 4, 5 or 6
Compressor Minimum On Time - Min .............................................. 3
1st Stage Compressor Minimum On Time - Min .............................. 3
2nd Stage Compressor Minimum On Time - Min ............................. 3
Indoor Heater Cycles Per Hour ........................................................ 2, 3, 4, 5 or 6
1st Stage Indoor Heater Cycles Per Hour ........................................ 2, 3, 4, 5 or 6
2nd Stage Indoor Heater Cycles Per Hour ...................................... 2, 3, 4, 5 or 6
3rd Stage Indoor Heater Cycles Per Hour ....................................... 2, 3, 4, 5 or 6
Indoor Heater Minimum On Time - Min ............................................ 1
1st Stage Indoor Heater Minimum On Time - Min............................ 1
2nd Stage Indoor Heater Minimum On Time - Min .......................... 1
3rd Stage Indoor Heater Minimum On Time - Min ........................... 1
Installer Setup Menus and Options
5.2