3. Maintenance
3.1 Failure code
Code
Reason
Remark
E1
IDU Room Temperature sensor failure.
(
IDU RT failure
)
IDU sensor and PCB.
E2
IDU Coil temperature sensor failure.
(
IDU
IPT failure
)
IDU sensor and PCB.
E4
Gas not enough
Please check the pressure in cooling
E5
System protection
For the high/low pressure valve model
E6
IDU PG Fan motor / DC fan motor works
abnormal
(
IDU failure
)
Fan motor, fan blade and PCB.
P7
Overheating protection on Heating mode.
Please check the troubleshooting for detail.
Note: Remote controller FAILURE CODE Querying function
As shown in the failure codes, some of the codes (Fb~bj) need to press remote control for inspection.
While unit on operation, press the ECO button 8 times with 8 seconds, the buzzer BIBI 2 times, you can
inspect the special failure code as Fb ~Fn, bj etc.