Start-Up
WSHP-SVX01W-EN
97
GEH*/GEV*090 (60 Hz)
GEH*/GEV*072 (50 Hz)
86
22.5
131-151
311-396
9-12
22-28
173-199
324-412
9-11
42-52
GEH*/GEV*090 (60 Hz)
GEH*/GEV*072 (50 Hz)
95
15.0
133-153
370-471
13-17
22-27
—
—
—
—
GEH*/GEV*090 (60 Hz)
GEH*/GEV*072 (50 Hz)
95
22.5
133-153
352-448
9-11
22-27
—
—
—
—
GEH*/GEV*120 (60 Hz)
GEH*/GEV*090 (50 Hz)
32
20.0
—
—
—
—
65-75
246-313
6-7
25-30
GEH*/GEV*120 (60 Hz)
GEH*/GEV*090 (50 Hz)
32
30.0
—
—
—
—
68-79
248-316
4-5
25-31
GEH*/GEV*120 (60 Hz)
GEH*/GEV*090 (50 Hz)
45
20.0
124-143
174-221
14-18
23-29
84-96
259-330
7-9
28-34
GEH*/GEV*120 (60 Hz)
GEH*/GEV*090 (50 Hz)
45
30.0
123-142
162-206
9-12
23-29
88-101
263-335
5-6
28-34
GEH*/GEV*120 (60 Hz)
GEH*/GEV*090 (50 Hz)
55
20.0
125-144
202-258
14-18
23-29
101-116
274-349
8-10
30-37
GEH*/GEV*120 (60 Hz)
GEH*/GEV*090 (50 Hz)
55
30.0
125-144
189-241
9-12
23-29
106-122
279-355
6-7
31-38
GEH*/GEV*120 (60 Hz)
GEH*/GEV*090 (50 Hz)
68
20.0
127-146
244-311
13-17
23-28
124-143
292-372
10-12
34-42
GEH*/GEV*120 (60 Hz)
GEH*/GEV*090 (50 Hz)
68
30.0
127-146
230-293
9-11
23-28
132-152
297-378
7-8
35-43
GEH*/GEV*120 (60 Hz)
GEH*/GEV*090 (50 Hz)
77
20.0
129-148
281-358
14-18
23-28
139-159
303-385
10-13
37-45
GEH*/GEV*120 (60 Hz)
GEH*/GEV*090 (50 Hz)
77
30.0
128-148
265-337
9-12
23-28
147-170
308-392
7-9
37-46
GEH*/GEV*120 (60 Hz)
GEH*/GEV*090 (50 Hz)
86
20.0
130-150
311-396
13-16
22-27
163-187
320-407
12-15
40-50
GEH*/GEV*120 (60 Hz)
GEH*/GEV*090 (50 Hz)
86
30.0
130-150
296-376
9-11
22-27
174-200
326-415
8-11
41-51
GEH*/GEV*120 (60 Hz)
GEH*/GEV*090 (50 Hz)
95
20.0
132-152
348-443
13-16
22-27
—
—
—
—
GEH*/GEV*120 (60 Hz)
GEH*/GEV*090 (50 Hz)
95
30.0
132-152
333-423
8-11
22-27
—
—
—
—
GEH*/GEV*150 (60 Hz)
GEH*/GEV*120 (50 Hz)
32
25.0
—
—
—
—
66-75
256-326
7-8
23-29
GEH*/GEV*150 (60 Hz)
GEH*/GEV*120 (50 Hz)
32
37.5
—
—
—
—
69-79
258-329
5-6
24-30
GEH*/GEV*150 (60 Hz)
GEH*/GEV*120 (50 Hz)
45
25.0
120-138
187-238
15-19
22-29
84-96
272-346
8-10
26-32
GEH*/GEV*150 (60 Hz)
GEH*/GEV*120 (50 Hz)
45
37.5
120-138
172-219
10-12
22-29
88-102
275-350
6-7
26-32
GEH*/GEV*150 (60 Hz)
GEH*/GEV*120 (50 Hz)
55
25.0
122-140
216-275
14-18
22-28
101-116
290-369
9-11
28-35
GEH*/GEV*150 (60 Hz)
GEH*/GEV*120 (50 Hz)
55
37.5
121-140
200-255
10-12
22-28
107-123
293-372
6-8
29-37
GEH*/GEV*150 (60 Hz)
GEH*/GEV*120 (50 Hz)
68
25.0
124-143
259-329
14-18
22-28
124-143
310-395
11-14
32-40
GEH*/GEV*150 (60 Hz)
GEH*/GEV*120 (50 Hz)
68
37.5
124-142
242-308
9-12
22-28
132-152
315-401
7-9
33-42
GEH*/GEV*150 (60 Hz)
GEH*/GEV*120 (50 Hz)
77
25.0
126-145
300-382
14-18
22-28
138-159
323-411
12-15
34-43
Table 54. Operating pressures in cooling/heating for GE* units (continued)
Operating Data
Model No.
Entering
Water
Temp
(°F)
Water
Flow
(GPM)
Cooling
Heating
Suction
Pressure
(psig)
Discharge
Pressure
(psig)
Water
Temp
Rise
(°F)
Air Temp
Drop
(°F DB)
Suction
Pressure
(psig)
Discharge
Pressure
(psig)
Water
Temp
Drop
(°F)
Air
Temp
Rise
(°F DB)
Содержание Axiom EXH Series
Страница 123: ......