Tranberg TEF 2870 Скачать руководство пользователя страница 4

R. Stahl Tranberg AS 

E

 

[email protected]

 | 

stahl-tranberg.com

Main office: Strandsvingen 6

 | 

N-4032 Stavanger

 | 

Norway 

T

 

+47 51 57 89 00

 |

 

F

 +47 51 57 89 50

Office Oslo: Luhrtoppen 2

 | 

N-1470 Lørenskog

 

|

 Norway 

T

 +47 24 08 44 10

SPARE PARTS

TEF 2870 Ex 

  

NAVIGATION LIGHT USER MANUAL

Description

Part No.

Light source, P28S 24V 40W

9400 049

Light source, P28S 230V 65W

9400 052

Mounting bracket for 1” pipe

0000 2600

Mounting bracket for 2” pipe

0000 2440

Lamp holder P28S

5088 0019

Gasket, junction box

5003 0164

O-ring, top lid

5000 0051

Cable gland M20 M20 Ø9,0 - 14,3mm

6222 010

Gland PG9 Ø3.5-8mm for restricted breathing test

5656

Material: 

Brass, lens of through coloured glass

Input voltage: 

According to installed light bulb. Max. 230V. 

Light source: 

40W for 24V versions. 

 

 

 

65W for 115/230V versions. 

Lamp base: 

P28S  

Power comsumption: 

40-65 Watt

Ingress protection: 

IP66

Cable gland: 

M20 Ø9,0 - 14,3mm

Area of use: 

Ex zone 2 and safe area.

Ex classification: 

      II3G Ex nR IIC Gc T5

Operating temperature: 

-52°C to +50°C

Certificate No. 

EC type examination MEDB000025U (DNV-GL)

 

EC Quality System MEDD000006D (DNV-GL)   

 

 

PRESAFE 14 ATEX 5436X 

 

IECEx PRE 14.0055X  

 

 

 

Special conditions: Resistance to impact is tested 
with reduced values, according to EN 60079-0 
26.4.2, “low risk of mechanical damage”.

Compliance standards:  

COLREG 72 as amended, Annex I/14, IMO Res 
A.694(17), IMO Res MSC.253(83) EN 60079-
0:2012, EN 60079-15:2010

TECHNICAL DATA

Содержание TEF 2870

Страница 1: ... consent of Tranberg AS The document or any part of it may not be translated to any other language without the written approval from Tranberg AS DISCLAIMER Tranberg AS endeavors to ensure that all information in this document is correct and fairly stated but does not accept liability for any errors or omissions SAFETY PRECAUTIONS Note that changes made to the product and or installation of compone...

Страница 2: ...ter intrusion condensation which should be removed immediately When cleaning use only mild detergents Alcohol or petroleum based products may damage lens paint or plastic components At intervals according to company routines the restricted breathing properties should be verified Remove stopping plug at test port PG9 See illustration below INSTALLATION INSTRUCTIONS The navigation light should be in...

Страница 3: ... 175 350 58 700 465 55 200 210 NOTE All measurements in millimeters All tolerances 1mm Minimum measurements indicated by an asterix 280A105557 Recommended mounting method of double tier navigation lights LAMP REPLACEMENT WARNING DO NOT OPEN MAINTAIN OR SERVICE IN AN AREA WHERE AN EXPLOSIVE ATMOSPHERE MAY BE PRESENT Use a 19mm wrench to screw off lid Twist off lamp and replace Screw lid back on Tig...

Страница 4: ...ted breathing test 5656 Material Brass lens of through coloured glass Input voltage According to installed light bulb Max 230V Light source 40W for 24V versions 65W for 115 230V versions Lamp base P28S Power comsumption 40 65 Watt Ingress protection IP66 Cable gland M20 Ø9 0 14 3mm Area of use Ex zone 2 and safe area Ex classification II3G Ex nR IIC Gc T5 Operating temperature 52 C to 50 C Certifi...