NAVIGATION LIGHT USER MANUAL

INTRODUCTION

Thank you for purchasing this product!
For installation, maintenance and assurance of a long life 
of this product, please follow this manual.

CONTENT IN BOX

The product is fully assembled, and ready for installation.

SAFETY PRECAUTIONS

Note that changes made to the product and/or installation 
of components which do not conform to the approval, 
may be a safety violation. The manufacturer will in no 
circumstance be held responsible for such  activity. For 
your health and safety, always use safety gear suited for 
the task. Be certain to follow codes, regulations and/or 
specific procedures that are related to the installation.

TOOLS REQUIRED

Regular tools required for installation.

• 

Wrench(es) suitable for selected M10 bolts for fixing 

navigation light to mast / ships structure.

• 

Flat screwdriver for opening junction box.

• 

27mm wrench for installing of cable gland.

• 

Small flat screwdriver for terminating wires.

IMPORTANT INFORMATION

The navigation lights are supplied with galvanic  isolators. 
These should be placed between the navigation light and 
the wall, thus preventing corrosion to either. There should 
be used acid resistant stainless steel fixing screws/bolts. 
Never paint navigation light or any of its components. Use 
only spare parts as described.

Gasket for junction box shall be replaced at intervals of one 
year. (Part No. 5003 0164). Gasket shall be of same type as 
original. One replacement gasket is included in shipment. 

The navigation light should be inspected according to 
Company routines. The manufacturer suggests regular 
check for water intrusion / condensation which should 
be removed immediately. When cleaning, use only mild 
detergents. Alcohol or petroleum based products may 
damage lens, paint or plastic components. 

At intervals according to company routines, the restricted 
breathing properties should be verified. Remove stopping 
plug at test port (PG9). See illustration below. 

INSTALLATION INSTRUCTIONS

The navigation light should be installed according to IMO 
regulations and other relevant rules and regulations for 
electrical installations onboard ships.

Consider the difference in material between the navigation 
light (seawater resistant brass) and the wall/mast it is to be 
installed on. 

Use galvanic isolators whenever there is a 

risk of corrosion.

• 

Fix navigation light to mast / ships structure using 2x 

M10 bolts (not supplied). Use acid resistant screws/

bolts. Tight firmly, max. 25 Nm. 

• 

Open junction box, install and secure electrical cable. 

The cable must be clamped near up to the navigation 

light according to relevant rules and regulations for elec-

trical installations onboard ships.

• 

Connect electrical wires. Max. 2.5mm

2

. Strip length 

8mm. Tightening force 0.6-0.8nm. Connect ground wire 

to M5 earth screw in junction box. 

• 

Screw on junction box lid. Max. tightening force: 5 Nm. 

Make sure that gasket is centered and covering the 

whole perimeter. 

• 

External bonding conductor. Connect bonding wire to 

point shown in illustration above. M8 screw.

For mounting and screening of side navigation lights, see 
illustration next page.

MAINTENANCE INSTRUCTIONS

Connect pressure meter / vacuum pump and conduct test 
according to IEC 60079-15(2010) 23.2.3.2.1.1. Note: PG9 
gland for connection of Ø3.5-8mm hose is included in 
shipment. Note: According to approval, test of restricted 
breathing properties is not required. 

Point for connecting bonding wire

Содержание TEF 2870

Страница 1: ... consent of Tranberg AS The document or any part of it may not be translated to any other language without the written approval from Tranberg AS DISCLAIMER Tranberg AS endeavors to ensure that all information in this document is correct and fairly stated but does not accept liability for any errors or omissions SAFETY PRECAUTIONS Note that changes made to the product and or installation of compone...

Страница 2: ...ter intrusion condensation which should be removed immediately When cleaning use only mild detergents Alcohol or petroleum based products may damage lens paint or plastic components At intervals according to company routines the restricted breathing properties should be verified Remove stopping plug at test port PG9 See illustration below INSTALLATION INSTRUCTIONS The navigation light should be in...

Страница 3: ... 175 350 58 700 465 55 200 210 NOTE All measurements in millimeters All tolerances 1mm Minimum measurements indicated by an asterix 280A105557 Recommended mounting method of double tier navigation lights LAMP REPLACEMENT WARNING DO NOT OPEN MAINTAIN OR SERVICE IN AN AREA WHERE AN EXPLOSIVE ATMOSPHERE MAY BE PRESENT Use a 19mm wrench to screw off lid Twist off lamp and replace Screw lid back on Tig...

Страница 4: ...ted breathing test 5656 Material Brass lens of through coloured glass Input voltage According to installed light bulb Max 230V Light source 40W for 24V versions 65W for 115 230V versions Lamp base P28S Power comsumption 40 65 Watt Ingress protection IP66 Cable gland M20 Ø9 0 14 3mm Area of use Ex zone 2 and safe area Ex classification II3G Ex nR IIC Gc T5 Operating temperature 52 C to 50 C Certifi...

Отзывы: