SECTION SIX: IF YOUR FIRE GOES OUT
If your grill fails to light or if the fire in the firepot goes out while cooking or
smoking, follow these steps:
1) Turn off the unit. Open barbecue lid, remove all food, cooking grill, angled
drip pan, and u-shaped firepot cover.
2) Remove ALL un-burnt barbecue pellets from inside and around the
firepot.
3)
Before replacing the u-shaped firepot cover
,
angled drip pan
and cooking grill,
restart your grill and confirm that ignition cycle is
working. (Hot rod should begin to turn red hot and pellets should
fall into firepot from auger tube.
4) If this procedure is not successful refer to the
Standard Lighting Procedure
section in your owner’s manual.
SECTION SEVEN: PARTS AND SERVICE
Part names are given in the front of this manual on the COMPONENT DIAGRAM PAGE.
To order parts: Find the part name on the component diagram page. Call or write your
Authorized Traeger dealer, distributor or Traeger Wood Pellet Grills LLC. Give us your
name, phone number, address, model and