Date: _______________________________________________
Tag: _____________________Qty: _______________________
Project: _____________________________________________
Engineer: ____________________________________________
Contractor:___________________________________________
Supplier: ____________________________________________
Quote#: _____________________________________________
Submitted by:_________________________________________
2
Engineering Data
Model RNC5-TPD
THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE
The cross-flow heat recovery core transfers heat between the two airstreams.
It is easily removed for cleaning or service.
MOTORS AND BLOWERS
Each Air stream has an independent motorized impeller. 120VAC
FILTERS
Washable air filters in exhaust and supply air streams.
DEFROST
The damper closes off the supply air from outside allowing the exhaust air to
recirculate through the unit.
CASE
Twenty gauge prepainted galvanized steel (G60) for superior corrosion resist-
ance. Insulated to prevent exterior condensation. Drain connections 1/2" (12
mm) OD.
MOUNTING THE HRV
Four threaded inserts at corners of case designed to accept four reinforced
polyester straps that are supplied with the unit.
CONTROLS- HRV System Control
HRV defaults to user selected speed from switch on top of cabinet when
plugged in. HIGH SPEED option is accessible by connecting remote controls
to designated terminals inside electrical box of HRV.
OFF(Standby)/LOW or OFF/HIGH speed operation is also available.
DUCT CONNECTIONS
4 - 5” (127 mm) duct connections.
Weight
61 lbs. (28 kg)
Shipping Weight
64 lbs. (29 kg)
All units conform to CSA and UL standards.
27”
(690 mm)
15”
(378 mm)
2-1/4”
(57 mm)
18-3/4”
(475 mm)
SPEED
SELECTION
SWITCH
TM
HEAT RECOVERY VENTILATOR
HEAT RECOVERY VENTILATOR
Dimensions
OPTIONAL ACCESSORIES
99-101 Crank Timer
99-116 Dehumidistat Ventilation Control
- Dehumidistat with ON/OFF
99-130 Dehumidistat Control
- Dehumidistat
99-132 20 Minute Fan Timer
- (3 wire) 20 gauge wire (min.) 100’ length
(max.)
99-185 Weatherhoods
, Two - 5” (125mm) c/w 1/4” (6mm) mesh screen
99-186 Weatherhoods,
Two - 6" (150mm) c/w 1/4" (6mm) mesh screen
99-2040 20/40 ON/OFF Dehumidistat
99-RECIRC
Recirculation Control
WARRANTY
Units carry a fifteen (15) year warranty on the heat recovery core and a 5
year replacement parts warranty.
1
2
3
0
20
40
60
80
100
120
140
160
180
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
1.1
Static Pressure (in w.g.)
A
ir
F
lo
w
(c
fm
)
3 - High Speed
*2 - Medium Low Speed
*1 - Low speed
* Manufacturers Data
*Sensible Efficiency - thermal **Latent Efficiency - moisture
Note: Effectiveness - based on temp. differential between the 2 airstreams
Efficiency - takes into account all power inputs
Performance
(H.V.I. certified)
Net supply air flow in cfm (L/s) against external static pressure
E
.S.P
(external static pressure)
[cfm (
L
/s)]
@ 0.1" (25 Pa)
169 (80)
@ 0.2" (50 Pa)
156 (73)
@ 0.3" (75 Pa)
149 (70)
@ 0.4" (100 Pa)
136 (64)
@ 0.5" (125 Pa)
126 (59)
@ 0.6" (150 Pa)
116 (54)
@ 0.7" (175 Pa)
103 (48)
@ 0.8" (200 Pa)
89 (42)
@ 0.9" (225 Pa)
77 (36)
@ 1.0" (250 Pa)
58 (27)
Max. Temperature Recovery
78%
Sensible Effectiveness
@ 66 cfm (31 L/s)
32°F (0°C)
74%
*Sensible Efficiency
@ 66 cfm (31 L/s)
32°F (0°C)
61%
*Sensible Efficiency
@ 76 cfm (36 L/s)
-13°F (-25°C)
63%
VAC @ 60HZ
120
WATTS / Low speed.
69
WATTS / High speed
147
Amp rating
1.7
Содержание RNC5-TPD
Страница 16: ...16 Wiring Diagrams Model RNC5 TPF LOW SPEED TO EXHAUST MOTOR TO SUPPLY MOTOR BLUE RED BROWN WHITE BLACK ...
Страница 23: ...23 ...
Страница 24: ......