09/20
Product Code: 2010T
Made in China to TQB Brands Pty Ltd specifications
Page 7
Visit us at www.tqbbrands.com.au
4.
OPERATION
Prior to each use always conduct a visual inspection checking for leaks and any abnormal conditions, such as cracked welds,
and damaged, loose, or missing parts.
VENTED HYDRAULIC PUMP
This
Porta Power
kit includes a vented hydraulic pump. The oil filler/breather screw is located in the top rear end of the
pump’s reservoir. The oil filler/breather screw must be opened by turning it in a counterclockwise direction two full turns
before operating the pump.
The pump may be operated in a horizontal position, or in a vertical position with the head pointing down as shown.
1.
Connect the hydraulic ram, hose and pump unit together, ensure that you have securely fastened the couplers before
pumping.
2.
Open the
oil filler/breather screw
(P7).
3.
Firmly close the release valve (P29) by turning it clockwise.
4.
Adjust the ram slowly to make the load coaxial with the ram.
5.
The pump can be used in any position from horizontal to vertical. Always keep the hose end of the pump downward
when it is not horizontal.
6.
Pump the handle (P37) up and down to extend the ram and apply hydraulic pressure.
7.
When work is done, SLOWLY and CAREFULLY turn the release valve (P29) counter-clockwise (never more than one
turn) to release the pressure until ram retracts to desired position.
8.
Close the oil filler breather screw (P7).
USING ATTACHMENTS
Some components in this set do not match the maximum pressure
rating of the pump and ram. ALWAYS monitor pressure, load or
position using suitable equipment. Pressure may be monitored by
adding a manifold and pressure gauge (not included). Using an inline
pressure gauge, you can calculate the applied force using the formula,
P = pressure in psi, and A = effective ram area in in2 . Ram Area is:
2.411 in2. When extension tubes in this kit are used, the rated capacity
is always reduced by 50% for each tube that is connected.
Attachments and extension tubes must always be aligned and fully
engaged so ram force is straight, avoiding an off-centre load condition.
If bowing or bending or ram or any attachment occurs during use,
"STOP", release pressure immediately and reconsider application.
PORTA POWER KIT
01
Hydraulic Pump
1
06
Ram Toe
1
02
Ram
1
07
Plunger Toe
1
03
Spreader
1
08
Wedge Head
1
04
Blow Mold Case
1
09
90° V Base
1
05a Extension 110mm
1
10 Male Connector
1
05b Extension 265mm
2
11
Serrated Saddle
1
05c Extension 365mm
1
12
Rubber Head
1
05d Extension 520mm
1
13
Flat Base