5.
STORAGE
This Air Conditioner should always be stored in a dry location on a level surface in an upright position.
When you stop using this Air Conditioner, you should clean the filter and keep it in a dry place, be careful not to damage the
Air Conditioner or filter.
Shut Down
Prior to shut down ensure the water in the condensation tank is empty. Always store the Air Conditioner in the upright
position.
6.
SERVICE & REPAIR
Any Air Conditioner found damaged in any way, or found to be worn or operates abnormally should be removed from service
until repaired by an authorised service agent. Owners and / or operators should be aware that repair of this product may
require specialised equipment and knowledge. Only authorised parts, labels and decals shall be used on this equipment.
Annual inspection of the Air Conditioner is recommended and can be made by an authorised repair facility to ensure that your
equipment is in optimum condition and that the equipment has the correct decals and safety labels specified by the
manufacturer.
TROUBLESHOOTING
Out-of-Operation
•
Power Cable loose
•
Fuse is burnt
•
Insert Power Cable into power supply
•
Repair or replace fuse
Out-of-Operation
•
Heat exchange surface is blocked
•
Hot exhaust blower fails
•
External temperature is too high
•
Compressor capacitator is damaged
•
Refrigerating system pipeline is clogged
•
Overly high or low input voltage
•
Compressor overheat & overload protection fails
•
Compressor motor fails
•
Clean heat exchange surface
•
Repair or replace hot exhaust blower
•
Unplug the heater and relocate
•
Replace compressor capacitor
•
Replace pipeline system
•
Ensure correct voltage
•
Wait 3 minutes and then restart the heater
•
Repair or replace compressor
Water Leakage
•
Drain pipe opening is clogged
•
Water tank position is not in place
•
Filter screen is dusty
•
Water tank is full
•
Clean drain pipe
•
Adjust water tank to the correct position
•
Clean filter screen
•
Empty water
Problem
Cause
Solution