Minimum Clearance

 

When the appliance is running, ensure the filter screen and the cold air ducting are 300mm 

minimum from the wall or other obstacles, and the hot exhaust pipe is 900mm minimum 

from the ceiling or other obstacles. 

 

 

 

 

 

Adjustment Air Range

 

The cold air duct can rotate left or right to 360degrees (hot air exhaust duct is installed) 

The cold air duct may be moved up or down to 150degrees 

The range of adjustment angle for the hot air exhaust duct is 45degrees 

 

 

  

WARNING -

Adjust the cold air duct prior to use and adjust the air out direction of 

the hot exhaust duct later.   When adjusting the flow angle of the cold air duct, grip the 

elbow for adjustment – do not hold on to the cold air duct directly.

 

 

 

Condensation Tank

 

A  5Litre  polyethylene  condensation  tank in the lower-front compartment of the unit 

collects evaporator-coil condensation moisture. When full, simply remove, drain, replace, 

and restart. Do not move the machine if the condensation tank is full of water. 

To empty the water in the condensation tank, ensure the end face on the tank handle is 

parallel. Rotate the control switch to 0. Empty the water in a resourceful manner and 

reinstall the condensation tank before restarting Air Conditioner. 

 

 

 

Pipe Drain (optional)

 

 

Remove the water tank and empty, push the optional drain pipe on to the appliance outlet 

inside  the tank recess. Then locate the drain pipe  through  the round hole in the 

corresponding side plate. Ensure the end of the pipe is below the Air Conditioner. 

 

 

 

 

 

Compressor Overload/Overheat Protection

 

The compressor overload protector will be activated to cut the power of the compressor to “Off” in the event of overly high 

or low voltage and/or overly high temperatures. 

When the overload protector is activated, the machine will only blow non-refrigerated air.  

Contact a qualified service technician if the overload protector is activated frequently. 

 

 

4.

 

MAINTENANCE 

Disconnect power prior to any maintenance 

Inspect the general condition of the Air Conditioner checking:  

 

for loose hardware 

 

cracked, bent, or broken parts, and 

 

any other condition that may affect the Air Conditioners safe operation 

 

Filter Screen

 

Clean the filter screen regularly using a vacuum cleaner to remove dust and dirt. When required the filter screen can be 

cleaned with a cloth and luke warm water.  Do not use chemicals. Leave to dry in a shaded area before reinstalling. 

NOTE: For effective cooling clean the filter at least every 2 weeks. 

 

 

Содержание 1033T

Страница 1: ...1033T Made in China to TQB Brands Pty Ltd specifications Visit us at www tqbbrands com au Product Code 1033T AIR CONDITIONER Specifications Cooling Capacity 6 5KW 22200Btu Power Unit 240V 50Hz Rated P...

Страница 2: ...w this equipment works Failure to observe any of the instructions contained in the manual could result in severe personal injury to the user or bystanders or cause damage to the equipment and property...

Страница 3: ...flammable substances or vapours such as alcohols pesticides gasoline etc DO NOT use the plug to start and to stop the unit Always use the control panel to start and to stop the unit Always turn off t...

Страница 4: ...models are equipped standard with heavy duty castors for easy portability TradeQuip Portable Industrial Air Conditioners bring in air from an outside source to cool its condenser cycling hot air to an...

Страница 5: ...uitable fixing tape The outdoor heat extraction duct must be water proof and protected from external debris falling into the exhaust duct point pipe downwards 3 OPERATION 1 Unlock the castors wheels a...

Страница 6: ...is parallel Rotate the control switch to 0 Empty the water in a resourceful manner and reinstall the condensation tank before restarting Air Conditioner Pipe Drain optional Remove the water tank and...

Страница 7: ...r Conditioner is recommended and can be made by an authorised repair facility to ensure that your equipment is in optimum condition and that the equipment has the correct decals and safety labels spec...

Страница 8: ...h Pressure Tube 1 10 Tube Head 2 33 Switch Fix Plate 1 56 Compressor 1 11 Hot Air Ring 1 34 Spiral Case Bracket 1 57 Compressor Cushion 3 12 Angle Protection 4 35 Volute Connection Plate 2 58 Pump Bol...

Страница 9: ...ed TQB Brands Pty Ltd repair agent This guarantee applies in lieu of any other guarantee expressed or implied and variations of its terms are not authorised Your TQB Brands Pty Ltd guarantee is not ef...

Отзывы: