68
smart Disk ID(D)
Parameters
Disk ID: 0-75. The Disk ID in system.
Description
The smart command used to get Disks S.M.A.R.T information. If the parameter is empty,
the command displays all disks information.
Examples
EEB00 >smart 25
Display S.M.A.R.T InformationDISK25
Information:
Vendor
:SEAGATE
Product
:ST4000NM0023
Revision
:0003
Logical Unit ID
:0x1234567812345678
Serial Number
:Z1Z0ZB2E00009350EE9V
User Capacity
:3726 GB
Max LBA
:7814037168 blocks
Logical block size
:512 bytes
Rotation Rate
:7200 rpm
Form Factor
:3.5 inches
Current Drive Temperature
:32 C ( 89 F)
Drive Trip Temperature
:40 C (104 F)
Manufactured Date
:in week 26 of year 2014
Cycle count over device lifetime
:10000
Accumulated start-stop cycles
:5988
Load-unload count over device lifetime :300000
Accumulated load-unload cycles
:5994
Blocks sent to initiator = 14207 Blocks received from initiator = 17817
Blocks read from cache and sent to initiator = 265
Number of read and write commands whose size <= segment size = 16 Number of read and
write commands whose size > segment size = 0 number of hours powered up = 707 hr 15 min
number of minutes until next internal SMART test = 52
subenclosure
Syntax
subenclosure enable subenclosure disable
Parameters
None.
Description
The subenclosure command used to display currently enclosure mode and to switch between
sub-enclosure mode and enclosure mode.
Содержание JBOD76
Страница 16: ...16 System Architecture Storage Carrier SAS dual path Storage Carrier SATA single path ...
Страница 24: ...24 Correct SATA drive connection 1 Correct SATA drive connection 2 Incorrect SATA drive connection 1 ...
Страница 31: ...31 4 Loosen the thumb screw on PDB1 5 Lift the PDB1 up and out to remove ...
Страница 41: ...41 6 Slide release tab and push system into rack 7 Insert the extension bracket to the outer member ...