TRACK STAR 1/5 Brushless Sensorless Car ESC Скачать руководство пользователя страница 8

8

SPECIFICATION

Constant/Burst Current
Compatible Motor
Compatible Car Type
Motor Limits
Resistance
Battery Cell Count
BEC Output
Size
Weight

200A/800A
Brushless Sensorless
1/5 Off Road, On Road

0.0002ohm
4-8S LiPo
6.0V/7.4V @ 15A
111x44x37mm (LxWxH)
359g (without wire)

KV

1100, 4 Poles 

Punch Rate Switch Point

1st Stage Punch Rate

2nd Stage Punch Rate

TH Input Curve

Throttle Dead Band

Throttle Status

Drag Brake

Brake Strength

Initial Brake

Brake Rate Switch Point

1st Stage Brake Rate

2nd Stage Brake Rate

Brake Input Curve

Throttle
Control

Brake
Control

50%

5

5

Line
0.080ms

10%

75%
=Drag Brake

50%

10

16

Line

Содержание 1/5 Brushless Sensorless Car ESC

Страница 1: ...controller s parameters can be record such as your battery volts amps draw motor rpm and controller temperature This is a good way to make sure that the rest of your setup is performing well within it...

Страница 2: ...verheating To avoid signal interference please always turn on the transmitter first THEN turn on the ESC Do the opposite sequence when powering off Never use faulty accessories a broken motor may dama...

Страница 3: ...f insulation from the end of each wire Pre tin the wire by heating the end and applying solder until it is thoroughly covered CAUTION By very careful not to splash yourself with hot solder Place the E...

Страница 4: ...beep once After that the red LED will blink the motor will ring like beep beep beep Then you could release the ESC switch button now Keep the throttle trigger in neutral position press the ESC switch...

Страница 5: ...SC will be shut down Note 1 After running at full load the ESC will be very hot Note 2 When the motor is running the ESC can t be poweredoff by pressing the switch when the motor stops working the ESC...

Страница 6: ...Rate 2nd Stage Punch Rate TH Input Curve Throttle Dead Band Throttle Status Section General Setting Throttle Control Forward Brake Normal 25 100 in 1 increment 9 6 42V in 0 1V increment 85 185 1 99 i...

Страница 7: ...pes to save Data Saving Time increment Single Start storage once entering in main program Cycle Press control storage entering in main program 0 1S 10S Voltage Current Throttle Current RPM ESC Tempera...

Страница 8: ...hm 4 8S LiPo 6 0V 7 4V 15A 111x44x37mm LxWxH 359g without wire KV 1100 4 Poles Punch Rate Switch Point 1st Stage Punch Rate 2nd Stage Punch Rate TH Input Curve Throttle Dead Band Throttle Status Drag...

Страница 9: ...g or solder tabs to short circuit or any damage caused by a crash flooding or natural disaster Because TRACKSTAR has no control over the connection use of the speed control or other related electronic...

Страница 10: ...NOTES 10...