Power
The PDU is powered from 48V dc using the provided cable RD306.
Terminal 1 of the PDU must be positive with respect to PIN 2,
shows the required connections for a positive
or negative supply option.
The PDU is protected against reverse polarity connections but if the
polarity is not correct the PDU will fail to function.
Table 2 Power Connections
Power
PIN 1
PIN 2
+ 48v supply
+ 48v
0V
- 48v Supply
0v
- 48v
2