Parameterization and configuration
TR-Electronic GmbH 2004, All Rights Reserved
Printed in the Federal Republic of Germany
Page 90 of 115
TR - ECE - BA - DGB - 00036 - 10
10/01/2014
8.8 TR-Mode High Resolution
Availability
● COx-58, TR0DAAAB.GS_
Configuration data
● 0xF1: 1 double word input data for position value, consistent
1 double word output data for preset adjustment value, consistent
Data Exchange
Byte
Bit
Input double word IDx
X+0
2
31
–2
24
Position value
X+1
2
23
–2
16
Position value
X+2
2
15
–2
8
Position value
X+3
2
7
–2
0
Position value
Byte
Bit
Output double word ODx
X+0
2
31
Preset execution with rising edge, see page 92
2
30
–2
24
Preset adjustment value
X+1
2
23
–2
16
Preset adjustment value
X+2
2
15
–2
8
Preset adjustment value
X+3
2
7
–2
0
Preset adjustment value
Parameter data, [x] = Default, Byte-Order = Big Endian
Byte
Parameter
Type
Description
Page
1
Count direction
Bit
Bit 0
0: increasing values [x]
1: decreasing values
Short diagnostics
(16 Byte)
Bit
Bit 1
0: Yes
1: No [x]
Commissioning
diagnostics
Bit
Bit 2
0: switched off [x]
1: switched on
2
Status-byte
Bit
Bit 1
0: switched off [x]
1: switched on
3-6
Total measuring range
Unsigned32
Total measuring range in steps
Default = 16777216 steps
7-10
Revolutions numerator
Unsigned32
Number of revolutions as fraction
Default = 4096 (numerator)
11-12 Revolutions denominator
Unsigned16
Number of revolutions as fraction
Default = 1 (denominator)
13-16
Lower limit switch
Unsigned32
Position value for lower limit switch
Default = 0
17-20
Upper limit switch
Unsigned32
Position value for upper limit switch
Default = 4096