Printed in the Federal Republic of Germany
TR-Electronic GmbH 2004, All Rights Reserved
10/01/2014
TR - ECE - BA - DGB - 00036 - 10
Page 87 of 115
8.6 TR-Mode Position
Availability
● CEx-58, TR09AAAB.GS_
Configuration data
● 0xF1: 1 double word input data for position value, consistent
1 double word output data for preset adjustment value, consistent
Data Exchange
Byte
Bit
Input double word IDx
X+0
2
31
–2
24
Position value
X+1
2
23
–2
16
Position value
X+2
2
15
–2
8
Position value
X+3
2
7
–2
0
Position value
Byte
Bit
Output double word ODx
X+0
2
31
Preset execution with rising edge, see page 92
2
30
–2
24
Preset adjustment value
X+1
2
23
–2
16
Preset adjustment value
X+2
2
15
–2
8
Preset adjustment value
X+3
2
7
–2
0
Preset adjustment value
Parameter data, [x] = Default, Byte-Order = Big Endian
Byte
Parameter
Type
Description
Page
1
Count direction
Bit
Bit 0
0: increasing values [x]
1: decreasing values
Short diagnostics
(16 Byte)
Bit
Bit 1
0: Yes
1: No [x]
Commissioning
diagnostics
Bit
Bit 2
0: switched off [x]
1: switched on
2
Teach-In function
Unsigned8
Bit 1-0
00: switched off no status [x]
10: switched off with status
11: switched on with status
3-6
Total measuring range
Unsigned32
Total measuring range in steps
Default = 16777216 steps
7-10
Revolutions numerator
Unsigned32
Number of revolutions as fraction
Default = 4096 (numerator)
11-12 Revolutions denominator
Unsigned16
Number of revolutions as fraction
Default = 1 (denominator)
13
Code SSI-Interface
Unsigned8
not supported
-
14
Code PROFIBUS-
Interface
Unsigned8
Bit 1-0
00: Gray
01: Binary [x]
10: Shifted Gray
15-18
Preset 1
Unsigned32 not supported
-
19-22
Preset 2
Unsigned32 not supported
-
23-26
Lower limit switch
Unsigned32
Position value for lower limit switch
Default = 0
27-30
Upper limit switch
Unsigned32
Position value for upper limit switch
Default = 4096
31
Data bits SSI-Interface
Unsigned8
not supported
-