![TR-Electronic IH 8 Series Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/tr-electronic/ih-8-series/ih-8-series_user-manual_1146707019.webp)
Printed in the Federal Republic of Germany
TR-Electronic GmbH 2016, All Rights Reserved
10/23/2019
TR - ECE - BA - GB - 0120 - 13
Page 19 of 40
4 Technical data
4.1 Safety
Functional safety
DIN EN 61508 Part 1-7 ...................................
S
afety
I
ntegrity
L
evel (SIL):
-
SDI, SS1, SS2, SOS, SLP, SLI, SCA ....
- 2
-
1
SLS, SSR, SSM, SLA, SAR ..................
- 3
EN ISO 13849-1 ..............................................
P
erformance
L
evel:
-
1
SDI, SS1, SS2, SOS, SLP, SLI, SCA ....
- PLd / Cat. 3
-
1
SLS, SSR, SSM, SLA, SAR ..................
- PLe / Cat. 3
Startup time ..............................................................
Time between POWER-UP and safe
incremental output
Variant 1 ..........................................................
≤
30 ms
Variant 2 ..........................................................
≤
50 ms
PFH / PFH
D
, "High demand" operating mode
Variant 1 ..........................................................
5.34 * 10
-9
1/h
Variant 2 ..........................................................
6.57 * 10
-9
1/h
Notice ..............................................................
Measuring system is used only in
applications with high or continuous
demand rate
MTTF
d
........................................................................
high
Variant 1 ..........................................................
1558 a
Variant 2 ..........................................................
622 a
avg
.......................................................................
medium (90 %)
Internal process safety time ...................................
Time between occurrence of an F-error
and alarm indication
Overall system .................................................
≤
1 ms
Process safety angle ...............................................
Angle between error occurrence and
alarm indication
Through channel-internal self-diagnosis .........
± 0.3510°, at 1024 periods;
± 0.1760°, at 2048 periods;
± 0.0879°, at 4096 periods;
in relation to the measuring system shaft
T
1
, repeat test (proof test) .......................................
20 years
1
according to EN 61800-5-2
2
The assessment occurred in accordance with Note 2 on Table 6 of EN ISO 13849-1