Parameterization and configuration
TR-Electronic GmbH 2008, All Rights Reserved
Printed in the Federal Republic of Germany
Page 88 of 109
TR - ECE - BA - DGB - 0068 - 01
06/19/2012
7.8 Description of the operating parameters
7.8.1 Count direction
Availability
PNO CLASS1 16 + 32
X
PNO CLASS2 16 + 32
X
TR-Mode Position
X TR-Mode Po Rpm.
–
The count direction defines whether ascending position values are output from the
measuring system if the measuring system shaft rotates clockwise or counter-
clockwise (view onto the measuring system flange).
7.8.2 Class 2 Functionality
Availability
PNO CLASS1 16 + 32
PNO CLASS2 16 + 32
X
TR-Mode Position
TR-Mode Po Rpm.
not supported!
not supported!
–
Defines the functional scope of the measuring system. Class 2 switched off means
only Class 1 functions are active in the measuring system; it does not scale the
position value and is not adjustable.
7.8.3 Commissioning diagnostics
Availability
PNO CLASS1 16 + 32
PNO CLASS2 16 + 32
X
TR-Mode Position
X TR-Mode Po Rpm.
not supported!
–
Defines whether the measuring system triggers a
"diagnosis alarm"
(OB82 for
SIMATIC S7) for an internal error (memory or value jump > 1 revolution), also see
Chapter
, page 105.