3 Technical data
3.1 Electrical characteristics
Supply voltage
................................................ 11-27 V DC, twisted in pairs and shielded
Current load
.................................................... < 200 mA at 11 V DC, < 110 mA at 27 V DC (unloaded)
Total resolution
..............................................
≤
24 bit (optional 25 bit)
Number of steps / revolution
........................
≤
8.192
Measurement range
Standard....................................................
≤
4.096 revolutions (12 bit)
Expanded ..................................................
≤
256.000 revolutions
Baud rate (adjustable)
................................... 125 kbit/s, line length up to 500 m
250 kbit/s, line length up to 250 m
500 kbit/s, line length up to 100 m
Station addresses
.......................................... 0 – 63, adjustable via DIP switches
Transmission
.................................................. twisted in pairs and shielded copper cable
CAN DeviceNet interface
............................... CAN field bus interface (opto-isolated)
Data transmission...................................... CAN bus driver (ISO/DIS 11898)
Terminating resistor
...................................... 121 ohm, selectable via DIP switches
Special features
.............................................. Programming of the following parameters via the
CAN-BUS:
- Direction of rotation
- Output code (binary, gray)
- Measuring length in steps
- Measuring length in revolutions
- Adjustment
- 7 special outputs
EMC
Immunity to disturbance .......................... DIN EN 61000-6-2: 2006
Transient emissions................................. DIN EN 61000-6-3: 2007