1 Features:
•
Precise non-contact measurements
•
Built-in laser pointer
•
Automatic selection range and Resolution to 0.1ºor 1º
•
°C/°F switchable button
•
Automatic Data Hold & Auto power off
•
The meter at 12 inches away measure 1 inch target
•
Backlit LCD display
2 Wide range application:
Food preparation, Safety and Fire inspectors, Plastic molding, Asphalt,
Marine and screen printing, measure ink and dryer temperature, Diesel and Fleet maintenance.
3 Field of View
The meter’s field of view is 12:1, meaning that if the meter is 12 inches from the target, the diameter of the object under test must be at least 1
inch. Other distances are shown below in the field of view diagram. Refer to the chart printed on the meter for more information.
Laser Beam
Sensor Beam
Fig: 1
1.
SAFETY
z
Use extreme caution when the laser beam is turned on.
z
Do not let the beam enter your eye, another person’s eye or the eye of an animal.
z
Be careful no to let the beam on a reflective surface strike your eye.
z
Do not allow the laser light beam impinge on any gas which can explode.
2.
SPECIFICATIES
z
General specifications
Display
3½ digital LCD screen with backlight
Measuring range / resolution
-50.0°C to 750°C /-58.0°F to 1382°F (0.1°C to 200°, 1° over 200°).
Response time
Less than 1 second.
Over range indication
LCD will show “1”.
Polarity
Automatic (no indication for positive polarity); Minus (-) sign for negative
polarity
Emissivity
0.95 fixed value
Field of view
D/S = Approx. 12:1 ratio (D = distance; S = spot (Has 90% encircled energy
at the focal point)
Diode laser
Output <1mW, Wavelength 630~670nm, class2 (II) Laser product.
Spectral response
8~14µm.
Power off
Automatic shut off after apprx. 7 seconds
Operating temperature
0°C to 50°C (32°F to 122°F).
Storage temperature
-20°C to 60°C (-4°F to140°F).
Distance(D) to Spot Size(S)
D:S=12:1
3.0@36
mm
inch
16mm
1.0@12
5.0@60
25@300 75@900
125@1500
INFRARED THERMOMETER
TE1005