10
DO NOT USE EXCESSIVE FORCE!
A light contact with the surface is sufficient. Using force
does not increase the measuring speed or improve the
accuracy of the measurement, but it does wear and/or
damage the sensor tip. Do not drag the probe over the
surface.
3. Select
Measure
in the start menu and press OK. The
instrument starts measuring.
Figure 4-2 Measuring without logging
The trend indicator between the parameter and the
reading indicates if the value is increasing or decreasing.
When a limit is exceeded, an audible alarm is triggered
and the alarm sign displayed next to the concerned
parameter.
4. Select
Hold
and press OK to freeze the measurements.
5. Select
Release
and press OK to start measuring again.
6. Select
Menu
and press OK to return to the start menu.
See Section 4.4 for detailed information on parameters.
4.2
The Log manual function
Select
Log manual
to store measurements batch by batch. An
entry is written to the selected batch every time you select
Hold.