1.

 

Getting started with the TQC CurveX 3 Basic  

The CurveX 3 Basic is an intelligent temperature data logging system that was specially 
designed to control curing processes in the coating industry. This manual describes how to 
use the CurveX 3 Basic logger and how to download the measurements to your computer 
with the Ideal Finish Analysis software. For the software installation instructions see the 
software manual. 

 

Quick start 

1.1
The information in the following steps should be sufficient to allow you to operate the 
CurveX 3 Basic without further use of this manual. For more detailed information we refer you 
to the remainder of the manual. See Figure 1 for more information about the interface 
positions. 

Step 1. 

Set the paint type and other parameters of the CurveX 3 Basic with the Ideal 
Finish Analysis software: 

 

Start Ideal Finish Analysis on the computer and connect the logger

 

 

Choose 

User settings

 in the 

Logger

 menu and follow the wizard. See 

the Ideal Finish Analysis help for details on the options. 

 

 

Disconnect the logger from the computer 

Step 2. 

Connect the thermocouple probes to the input points at position 7 of the 
CurveX 3 Basic. 

Step 3. 

Attach the sensors to the object to be measured.

Step 4. 

Press and hold down the POWER button (position 1) for one second to 
switch on the CurveX 3 Basic. 

Step 5. 

Start the recording process by pressing the START button (position 2). The 
logging, paint and battery leds (position 4, 5 and 6) will blink once. The 
logging led will blink blue at the specified logging interval.   

Step 6. 

Place the CurveX 3 Basic logger inside the insulation box. Make sure the 
insulation system is set up properly, as specified in the manual of the 
insulation box chosen. The cables are guided through the cable outlet and 
the cover is closed securely, using the gasket to ensure optimal heat 
protection. 

Step 7. 

Send the system through the oven and then remove the instrument from 
the box as soon as possible. The paint led (position 5) blinks green after a full 
cure or red after a partial cure. The cure specification is set in the software, 
see the Ideal Finish Analysis help for more details (Logger menu – User 
settings). 

Step 8. 

Stop the recording process by pressing the STOP button (position 3).

Step 9. 

Download the results with Ideal Finish Analysis:

 

Choose 

Download all data to PC…

 in the 

Logger

 menu of Ideal Finish 

Analysis and follow the wizard.  

Содержание CurveX 3 Basic

Страница 1: ...1 CurveX 3 Basic Article number CX3005 User Guide V1 1 0916...

Страница 2: ...rom natural wear and tear mechanical or chemical damage an act of God or non compliance with the operating instructions shall be excluded from the warranty as well as mechanical interference by the cu...

Страница 3: ...ress 7 2 2 Logger menu Real Time 7 2 3 Logger menu User Settings 8 2 4 Logger menu Configure Test 8 2 5 3 The CurveX 3 Basic thermocouple connectors 9 3 1 1 Connecting the probes 9 4 CurveX 3 Basic pr...

Страница 4: ...uple probes to the input points at position 7 of the CurveX 3 Basic Step 3 Attach the sensors to the object to be measured Step 4 Press and hold down the POWER button position 1 for one second to swit...

Страница 5: ...ogging led Blue led indicates CurveX 3 Basic is logging 5 Paint led Red partial cure Blue active Green full cure 6 Battery led Shows battery status when powered on Red 25 Blue 25 to 75 Green 75 7 Ther...

Страница 6: ...rtly used Loggings that take longer than 16 000 readings are stopped at reading number 16 000 The maximum number of batches that can be stored is 10 CurveX 3 Basic tasks 1 3 This table below describes...

Страница 7: ...ing the POWER button see figure 1 position 1 and start the Ideal Finish Analysis software Step 2 Connect the USB connector to the CurveX 3 Basic see figure 1 position 8 Step 3 Connect the other side o...

Страница 8: ...communicate with a computer use the USB cable to connect it to an available port on the computer Once connected communication can be tested by taking the following steps Step 1 Connect the data logger...

Страница 9: ...ial infrared probes Figure 2 The position of the sensors on the object can be stored in Ideal Finish Analysis The position will then also be available in the reports Remark Make sure that the probe ca...

Страница 10: ...is part in order to align the sensor element with the surface to ensure good contact Take the clamp between your thumb and forefinger Check which jaw has the sensor element and place the probe at the...

Страница 11: ...datasheet for the maximum time and temperature use 4 1 1 Preparing for measurement Step 1 Make sure the box is at room temperature Step 2 Place the CurveX 3 Basic data logger with the probes already c...

Страница 12: ...cabin The battery employed in our CurveX 3 Basic is a generic single cell Lithium Ion battery 3 7V 1400mAh The battery employed in the CurveX 3 Basic has a capacity of 5 18 Watt hours and is rated fo...

Страница 13: ...by Weight 190 g 6 7 oz TQC Ideal Finish Analysis software Supported Operating Systems Windows Vista Windows 7 and Windows 8 8 1 Platform 32 b or 64 b Memory 32 MB Required Hard Disk space 128 MB Curve...

Страница 14: ...14...

Страница 15: ......

Страница 16: ......

Отзывы: