![TQ-Systems MBa335x Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/tq-systems/mba335x/mba335x_user-manual_1146561025.webp)
User's Manual l MBa335x UM 0202 l © 2018, TQ-Systems GmbH
Page 18
Table 20:
Parameter TPS5450 (VCC12V)
Parameter
Min.
Typ.
Max.
Unit
Remark
Output voltage
12.058
–
12.061
V
DC load
Output current
–
–
3
A
Ripple
–
–
20
20
–
–
mV
pp
mV
pp
(I
OUT
= 1 A)
(I
OUT
= 3 A)
Load step change – add load
drop
Control time
–
–
1.5
0.5
–
–
V
ms
I
OUT
= 0 A 2 A
Load step change – remove load
overshot
Control time
–
–
0.7
20
–
–
V
µs
I
OUT
= 2 A 0 A
Table 21:
Parameter LT3503 (VCC1V5)
Parameter
Min.
Typ.
Max.
Unit
Remark
Output voltage
1.492
–
1.501
V
DC load
Output current
–
–
0.75
A
Ripple
–
–
6
8
–
–
mV
pp
mV
pp
(I
OUT
= 0.375 A)
(I
OUT
= 0.75 A)
Load step change – add load
drop
Control time
–
–
50
20
–
–
mV
µs
I
OUT
= 20 mA 0.75 A
Load step change – remove load
overshot
Control time
–
–
30
20
–
–
mV
µs
I
OUT
= 0.75 A 20 mA
Illustration 11:
Position of connectors X26, X27
Table 22:
Power supply connectors
Manufacturer / Number
Description
Cui Stack / PJ-102BH
DC jack 2.5 mm / 5.5 mm, nominal: 5 A / 24 V
Lumberg / KRM2
2-pin screw terminal, 250 V / 15 A
X26 X27