TPI FPQ 3310 Series Скачать руководство пользователя страница 3

3

3310 SERIES

TROUBLE SHOOTING
Symptom

Possible Fault(s)

Remedy

Heater Does Not Operate

1. Electrical Circuit Open

1. A. Close electric circuit.

    B. Verify correct supply Voltage

    C. Adjust thermostat to higher setting.

2. Defective Thermostat

2. Check continuity with an ohm meter.

    Replace defective part if necessary.

3. Thermal Cut Out Open

    (Alarm Light On)

3. A. Remove any obstruction from front of heater.

    B. Verify correct supply voltage.

Heater On But Fan Does Not Operate

1. Fan Motor Failure

1. A. Verify correct supply voltage.

    B. Check motor wiring connections.

    C. Replace defective motor if necessary.

9. Field Conversion For Lower Wattage: 

To convert heater to a lower wattage rating. 

Remove  (Red  Jumper)  from  heating        element 

(See WD1, WD2, WD3 and WD4). The wattage will 

be reduced to half of the nameplate wattage. (See 

Figure 3 for model numbers rated dual wattage)

MODEL NO.

VOLTAGE

WATTAGE

AMPERAGE

E3313RP

120

1500

12.5

120

750

6.25

HF3315RP

240/208

3000/2250

12.5/10.8

240/208

1500/1125

6.25/5.4

HF3316RP

240/208

4000/3000

16.7/14.4

240/208

2000/1500

8.3/7.2

FIGURE 3

WD-1 

3310 with Summer Fan Switch, Double Pole T-Stat and (Optional Disconnect Switch)  

WD-2 

3310 with Summer Fan Switch, Single Pole T-Stat and (Optional Disconnect Switch)

WD-3 

3310 with (Optional Double Pole T-Stat and Disconnect Switch)

WD-4               3310 with Single Pole T-Stat and (Optional Disconnect Switch) 

AIL  

Alarm Indicator Lights

IMPORTANT: OWNER SHOULD RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE

120-277V WHITE

208-240V BLACK

LINE

BLAC

K

GN

D

WD-1

MOTOR

ELEMEN

T

AIL

THERMOSTAT

THERMOSTAT

MOTOR

THERMAL 

PROTECTO

R

ELEMEN

T

AIL

THERMOSTAT

120-277V WHITE

208-240V BLACK

GN

D

LINE

BLAC

K

ELEMEN

T

AIL

OPTIONAL

RED JUMPER

RED JUMPER

RED JUMPER

RED JUMPER

120-277V WHITE

208-240V BLACK

LINE

BLAC

K

GN

D

MOTOR

THERMAL 

PROTECTO

R

ELEMEN

T

AIL

120-277V WHITE

208-240V BLA

C

K

LINE

BLAC

K

GN

D

DISCONNECT

OPTIONAL

DISCONNECT

OPTIONAL

THERMOSTAT

DISCONNECT

OPTIONAL

DISCONNECT

 

OPTIONAL

WD-2

WD-3

WD-4

MOTOR

THERMAL 

PROTECTO

R

THERMAL 

PROTECTO

R

Form 9821 

ECO 1-7472 

REV. 10-19-18

Содержание FPQ 3310 Series

Страница 1: ...ce leads to two black leads on 208 240 volt models and to black and white leads on 120 277 volt models attach ground lead to green wire with approved connectors Comply with all national and local codes D Attach wiring compartment cover D to assembly with screw C 5 FINAL STEPS A Clean all construction dirt and debris from inside heater B Attach front grille F with four screws L A parts bag containi...

Страница 2: ...nect panel or operate internal disconnect switch if provided 8 Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric chock or fire or damage the heater 9 To prevent a possible fire do not block air intakes or exhaust in any manner 10 A heater has hot and arcing or sparking parts inside WARNING Do not use it in area where gasoline paint or ...

Страница 3: ... 120 750 6 25 HF3315RP 240 208 3000 2250 12 5 10 8 240 208 1500 1125 6 25 5 4 HF3316RP 240 208 4000 3000 16 7 14 4 240 208 2000 1500 8 3 7 2 FIGURE 3 WD 1 3310 with Summer Fan Switch Double Pole T Stat and Optional Disconnect Switch WD 2 3310 with Summer Fan Switch Single Pole T Stat and Optional Disconnect Switch WD 3 3310 with Optional Double Pole T Stat and Disconnect Switch WD 4 3310 with Sing...

Страница 4: ... MODÈLE TENSION PUISSANCE AMPÉRAGE E3313RP 120 1500 12 5 120 750 6 25 HF3316RP 240 208 3000 2250 12 5 10 8 240 208 1500 1125 6 25 5 4 HF3316RP 240 208 4000 3000 16 7 14 4 240 208 2000 1500 8 3 7 2 FIGURE 3 WD 1 3310 avec commutateur pour ventilateur d été thermostat bipolaire et interrupteur optionnel WD 2 3310 avec commutateur pour ventilateur d été thermostat unipolaire et interrupteur optionnel...

Отзывы: