background image

Form 9766      Rev.-   ECO 1-7322    9/17

 

ATTENTION: 

The table to the right provides 

definitions of the signal words that 

can be found throughout this 

manual.  These signal words are 

used to express the severity of 

the hazard at hand.  The signal 

words are generally used in 

conjunction with safety symbols 

that correspond to the text for that 

particular hazard.  As you read 

this manual, refer back to this 

table when you are unsure of the 

signal word definition. 

The Fostoria TO-SK-1 Tip-Over Switch is designed 

to provide a safe way to quickly shut off power 

to FSP-43 and FSP-95 Series heaters if they are 

accidentally tipped over.  It mounts directly to the 

terminal box on these cart heaters. 

•  Use with voltages up to 600 VAC. 

 

 

•  50 amps maximum load.

•  50/60 Hz rating.

•  Can be used in single and three phase 

applications.

•  The power switch illuminates when in use.

SPECIFICATIONS

INDEX

General Description & Use

Page 2

Specifications

Page 2

Installation

Page 3

Wire & Wire Specifications

Page 4 and 5

Signal Word Definitions

DANGER: Indicates an imminently hazardous 

situation which, if not avoided, 

will

 result in 

death or serious injury.
WARNING: Indicates an imminently hazard-

ous situation which, if not avoided, 

could

 result 

in death or serious injury.
CAUTION: Indicates an imminently hazardous 

situation which, if not avoided, 

may

 result in 

death or serious injury.
CAUTION: Indicates an imminently hazardous 

situation which, if not avoided, 

may

 result in 

death or serious injury.

As defined in ANSI Z535-4-2002

ELECTRICAL SHOCK HAZARD 

FIRE HAZARD

•  Serious injury or death may 

occur.

•  Not for indoor residential use.

•  Do not use outdoors in wet 

conditions and in unprotected 

locations.

•  Do not use in wash down 

applications.

2

Содержание fostoria FSP-43

Страница 1: ...Form 9766 Rev ECO 1 7322 9 17 TO SK 1 Tip Over Switch Kit For FSP 43 AND FSP 95 REFER TO COMPLETE INDEX OF INFORMATION ON PAGE 2 TPI Corporation P O BOX 4973 JOHNSON CITY TN 37602 www tpicorp com ...

Страница 2: ...rating Can be used in single and three phase applications The power switch illuminates when in use SPECIFICATIONS INDEX General Description Use Page 2 Specifications Page 2 Installation Page 3 Wire Wire Specifications Page 4 and 5 Signal Word Definitions DANGER Indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING Indicates an imminently ha...

Страница 3: ...at were removed from the 4x4 wiring box and the two lockwashers supplied See illustrations 2 and 3 3 Re attach the conduit to the TO SK 1 4 Wire the heater to the load side of the TO SK 1 contactor see heater wiring diagram for single or three phase connection Connect designated transformer leadwire to pigtail on L1 of contactor see Wiring Diagram A See heater data label for correct line voltage 5...

Страница 4: ... GROUND GROUND FROM HEATER TRANSFORMER BLUE WHITE 12 3 LEADS TO HEATING ELEMENTS POWER SOURCE PRIMARY SIDE LEAD COLORS 600V GRAY 480V BLACK RED 277V BROWN 240V ORANGE 208V RED L3 L2 L1 CONTACTOR ROCKER SWITCH TIP OVER SWITCH TIP OVER SWITCH T3 T2 T1 4 1 2 3 4 FOR 3 OPERATION L1 1 4 L2 2 L3 3 FOR 1 OPERATION L1 1 3 L2 N 2 4 WIRING SCHEMATIC L1 L2 N FSP 4327 1 AND FSP 9527 1 MODELS FOR ALL OTHER MOD...

Страница 5: ...804600 8 4 SO 08805100 14 4 SO 08804900 6 4 SO 03164001 12 3 SO 08804500 4 3 SO 08805300 12 4 SO 03164201 2 3 SO 08804700 10 3 SO 08804400 TABLE A Heater Model Kw Volts Amps Type SO Cable Size Plug Size 3 Ph Plug Size 1 Ph 3 PH 1 PH 3 PH 1 PH FSP 4320 3 4 3 208 11 94 20 67 12 4 10 3 20A 250V 4 WIRE 30A 250V 3 WIRE FSP 4324 3 4 3 240 10 36 17 91 14 3 12 3 20A 250V 4 WIRE 30A 250V 3 WIRE FSP 4327 1 ...

Отзывы: