![TPI Fostoria FHK Series Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/tpi/fostoria-fhk-series/fostoria-fhk-series_manual_1146246015.webp)
ISSUE DATE 12-12-08 REV. DATE 12-12-08 REV. LEVEL: 01 ECN: GP-5179 OIPM P/N 3420466 PG
15
OF
20
REFLECTOR REPLACEMENT: FHK-6 & FHK-13
ELECTRICAL SHOCK HAZARD
•
Serious injury or death may
occur.
•
Disconnect heaters from
electrical supply before
replacing parts.
To replace the reflector:
1. Lay heater face down and remove the cart from the
heater by taking off the (4) jam nuts as shown in
Illustration 10.
2. Lift the back shield and (4) washers off the heater.
3. Remove the (2) support clips from the front of the
reflector.
4. Remove (4) jam nuts that secure the extrusion to
the housing. The extrusion and reflector will now
come out of the housing.
5. Slide the reflector out of the extrusion and discard.
6. Peel protective film from new reflector, and then place
the reflector in the extrusion. Make sure it is secured in
slots in extrusion.
7. Reattach extrusion, back shield and cart, using
hardware removed in previous steps.
8. Replace support clips in the front of the reflector.
9. Finish reassembly of heater by completing Steps 13
and 14 on page 14.
Illustration 10
Jam nut
Cart
Back shield
Washer
Jam nut
Reflector
Extrusion
Support clips
ACCESSORIES
The kits shown below are optional controls for the FHK Series heaters.
DC-SK-1
Disconnect switch
Part No.: 05893702
-Wall mountable for all FHK models
-Mounts directly on FHK-6 & FHK-13
models only
TO-SK-1
Tip-over switch
Part No.: 04858102
-Mounts directly on FHK-
6 & FHK-13 models only
GF-SK-1
Ground fault sensor switch
Part No.: 04860202
-Wall mountable for all FHK
models
-Mounts directly on FHK-6 &
FHK-13 models only