CRIMP NUT
WIRE NUT
GND
GND
3900 SERIES BASEBOARD
SUPPLY
DOUBLE POLE
DISCONNECT
SWITCH
SHOWN WIRED RIGHT END
ELEMENT
OVER TEMP. LIMIT CONTROL
GND
LEFT JUNCTION BOX
GND
RIGHT JUNCTION BOX
3700 SERIES BASEBOARD
SUPPLY
DOUBLE POLE
DISCONNECT
SWITCH
LEFT JUNCTION BOX
RIGHT JUNCTION BOX
CRIMP
NUT
ELEMENT
TEMP.
LIMITING
DEVICE
SHOWN WIRED LEFT END
INSTALLATION
INSTRUCTIONS
INSTALLATION
INSTRUCTIONS
INSTALLATION INSTRUCTIONS
DISCONNECT SWITCH MODEL 3900DS
CAUTION:
Disconnect supply service to baseboard to avoid electrical shock.
All wiring connections must conform to the National Electric Code and local codes having
jurisdiction.
NOTES:
*Do not eliminate or bypass the thermal cutout.
*Do not exceed the nameplate rating.
*The inbuilt accessory can be mounted in either end of the baseboard heater.
1. Remove the baseboard junction box cover and retain the screw.
2. Remove the wire nut in the junction box (Do not remove the crimp nut connection).
3. Make the connections per the wiring diagram. Connect the wires marked “Line” to the supply.
Connect the wires marked “Load” to the baseboard. Make sure all connections are secure.
4. Install disconnect switch cover assembly to baseboard junction box and secure with screw
previously removed.
5. Restore power and check for proper operation.