7.

 

Remove the cosmetic rings from the side box figure 7.1. Place the cosmetic over the end 
of the delivery unit flex arm Figure 7.2. Once in place, route all lines and feed them 
through the bushing assembly shown in figure 7.3. Verify that the arm seats completely 
down on the bushing assembly. Lower the cosmetic ring to cover the seam between the 
arm and utility center cover.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

8.

 

Route the delivery system foot control and feed it through the bottom of the PMU figure 
8.1. Make the following connections from your foot control to the tubing within the PMU 
side box. Large yellow to Grey on foot control X2. Small grey on foot control to the clear 
tubing to unit head for water relay connection. Figure 8.2.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

Figure 7.1 

Figure 7.2 

Figure 7.3 

Figure 8.1 

Figure 8.2 

Содержание Mirage 2.0

Страница 1: ...1 www tpcdental com Mirage Dental Delivery Unit Model 2 0 Installation Instructions TPC 851 S Lawson St City Of Industry CA 91748 P626 810 4337 Fax 626 810 4245...

Страница 2: ...y 3 Installation and coordination 4 Optional Cuspidor Installation 10 Cuspidor Plumbing Connections 11 Junction Box Connections 12 Post Mount Utility Center Adjustments 13 Pressure Adjustments Tension...

Страница 3: ...lity center Master controls attached to the umbilical for air and water Wet dry foot control HEV SE valves with tubing Water Bottle 1000 ml 3 Optional 2000 C Cuspidor Cuspidor Bowl rinse spout Cuspido...

Страница 4: ...he chair bracket has a total of 8 set screws Use the lower set screws to adjust the PMU left right front and back This will make large adjustments to the tilt of the post that is inserted into the bra...

Страница 5: ...so verify if the PMU is aligned straight with dental chair armrest 4 Verify the PMU is level before tightening the set screws on chair bracket There are 8 set screws that will be used for leveling If...

Страница 6: ...not get damaged This side cover will remain detached until the end of the installation 6 Remove the plastic covers on the top of the PMU box Figure 6 1 Install the light post as shown in the middle h...

Страница 7: ...on the bushing assembly Lower the cosmetic ring to cover the seam between the arm and utility center cover 8 Route the delivery system foot control and feed it through the bottom of the PMU figure 8 1...

Страница 8: ...o Orange in flex arm Signal Air return from master switch Black from umbilical to black in flex arm Return signal air from master control Small Grey from foot control to clear tubing in flex arm Water...

Страница 9: ...rews from the touchpad bracket Install the washers and nylon nuts for the touchpad screws shown in figure 11 1 Connect the Molex connector from the touchpad to the wire harness shown in figure 11 2 Re...

Страница 10: ...rolled via the touchpad If you don t require a touchpad controller operatory light you can connect the power to the ports on the bus bar labeled 24V this will provide constant 24V power to the LED ope...

Страница 11: ...he cuspidor Figure 16 1 Install cuspidor strainer Figure 16 2 Install the bowl rinse spout figure 16 3 Press the spout firmly into place Route the cuspidor power harness to the backside of the PMU Fig...

Страница 12: ...om the cuspidor to the water solenoids mounted inside the post mounted utility center Figure 19 1 The clear water line will connect to the solenoid on the left The blue line will connect to the soleno...

Страница 13: ...FF position to decompress the bottle system prior to removal If you need to increase the water pressure from the bottle system Remove the side cover of the post mounted utility center figure 2 2 Locat...

Страница 14: ...press the disc on the foot control to supply air to the unit head If a handpiece is removed from its holder that will be the active handpiece Using the toggle on the foot control will turn the water o...

Страница 15: ...15 www tpcdental com 7 The mirage 2 0 delivery unit has a water quick disconnect This is located under the post mounted utility center See figure 7 1 for location...

Страница 16: ...that exits the back end of the master control valve The master control for the water line is identified by the large blue line that exits the back of the master control valve 22 Once the connections a...

Страница 17: ...Adjustments 2 In a situation that you need to add tension to the delivery unit flex arms please see the following locations NOTE tension adjustments are only a temporary fix for drifting arms If your...

Страница 18: ...loose use the two adjustment screws in the center on each side to level the head To adjust the unit head tilt remove the flex arm end cap closest to the delivery unit head Loosen the stop nut and usi...

Страница 19: ...ry unit arm 1 Yellow 6 X 4 Supply line T to unit head 2 Black 6 X 4 from output from foot control 3 Small Yellow Small Yellow Master Switch return 4 Small Gray Small Gray supply line to master switch...

Отзывы: