background image

Standard

Protocol

Interface

EU declaration of conformity 

TP-Link hereby declares that the device is in compliance with the essential requirements and other relevant 

provisions of directives 2014/30/EU, 2014/35/EU, 2009/125/EC, 2011/65/EU and (EU)2015/863.
The original EU declaration of conformity may be found at https://www.tp-link.com/en/ce.

Specifications

General Specifications

Network Media (Cable)

MAC Address Table
Switching Capacity
Transfer Method
MAC Address Learning

Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity 

Environmental and Physical Specifications 

˚

C to 40 

˚

C (32 

˚

F to 104 

˚

F)

-40 

˚

C to 70 

˚

C (-40 

˚

F to 158 

˚

F)

10% to 90%RH non-condensing

5% to 90%RH non-condensing

IEEE802.3, IEEE802.3u, IEEE802.3ab, IEEE802.3an
IEEE802.3bz, IEEE802.3x, IEEE802.1p
CSMA/CD 
100BASE-TX:
2-pair UTP/STP of Cat. 5 or above (maximum 100 m)
1000BASE-T:
4-pair UTP/STP of Cat. 5e or above (maximum 100 m)
2.5GBASE-T:
4-pair UTP/STP of Cat. 5e or above (maximum 100 m)
5GBASE-T:
4-pair UTP/STP of Cat. 5e or above (maximum 100 m)
10GBASE-T:
4-pair UTP of Cat 6 (maximum 55 m) or STP of Cat 6, 

6a, 7 (maximum 100 m)
5 100M/1G/2.5G/5G/10G RJ45 Ports
Auto-Negotiation/Auto MDI/MDIX
32K
100 Gbps
Store-and-Forward
Automatically learning, automatically aging

QoS (802.1p/DSCP), 802.3x flow control

100Base-TX: 148810 pps/port
1000Base-TX: 1488095 pps/port
2.5GBase-TX: 3720238 pps/port
5GBase-TX: 7440476 pps/port
10GBase-TX:14880952 pps/port

Q1. Why is the Power LED not lit?

Q2. Why are the right and left LEDs not lit when a device is 

connected to the corresponding port?

Frequently Asked Questions (FAQ)

The Power LED should be lit when the power system is working 

normally. If the Power LED is not lit, check as follows:

A1:

 Make sure the power adapter is connected to the switch with 

power source properly.

A2:

 Make sure the voltage of the power supply meets the requirements 

of the input voltage of the switch. 

A3:

 Make sure the power source is on. 

It is recommended that you check the following items:

A1:

 

Make sure that the cable connectors are firmly plugged into the 

switch and the device.

A2:

 Make sure the connected device is turned on and works normally.

A3:

 Make sure the cable category and length meet the standards listed 

in General Specifications. 

For technical support and other information, please visit 

https://www.tp-link.com/support

, or simply scan the QR 

code. 

If you have any suggestions or needs on the product 

guides, welcome to email 

[email protected]

.

To ask questions, find answers, and communicate with TP-Link users 

or engineers, please visit 

https://community.tp-link.com

  to join 

TP-Link Community.

Safety Information

Keep the device away from water, fire, humidity or hot environments.

Do not attempt to disassemble, repair, or modify the device. If you need service, please contact us.

Do not use damaged charger or USB cable to charge the device.

Do not use any other chargers than those recommended.

Adapter shall be installed near the equipment and shall be easily accessible.

Place the device with its bottom surface downward.

The plug on the power supply cord is used as the disconnect device, the socket-outlet shall be easily 

accessible.

Use only power supplies which are provided by manufacturer and in the origin packing of this

product. If you have any questions, please don’t hesitate to contact us.