COOLING MODE OPERATION
• Compressor stops when the room temperature is cooled down to the designated temperature.
• Compressor restarts when room temperature is raised to +0.7
°
C higher than the designated temperature.
OPERATION DETAILS
ROOM TEMP.
DESIGNATED TEMP.
INDOOR FAN
ON
ON
OFF
ON
ON
ON
ON
OFF
COMPRESSOR
0.7
OFF
OFF
TIME DELAY SAFETY CONTROL FUNCTION - FOR PROTECTION OF COMPRESSOR
• Compressor will not restart, in any operation modes, for 3 minutes after its stop.
• Compressor does not stop during the first 3 minutes of its operation even if the room temperature reaches to
the designated temperature, except changing setting temperature.