SERVICE FUNCTION EXPLANATION
Emergency Operation
• Use this operation only when the remote controller is out of order or lost.
• When the emergency operation switch is pressed, beep starts once, which
means the start of this operation.
• In this operation, the system automatically selects the operation modes, cooling
(or heating when available) according to the room temperature, as follows.
• It is not possible to operate in dry mode.
Test Operation
Test operation switch is same as emergency one.
• Use this operation only for testing the performance of the machine in the condition
where the room temperature is less than 16
°
C.
• Continue to press the test operation switch for more than 5 seconds.
After you hear twice beep, release your finger from the switch: the cooling
operation starts with the air flow speed “HI.”
• If the test operation switch is pressed more than 10 seconds, it doesn’t work.
• After 30 minutes, test operation ends automatically.
When two indoor units used in the same room, interference of the signals may happen. To avoid this, alternative
signal model B can be selected by the following. (Ex-factory setting is mode A)
• Remote controller side
: Have “J1” on the PC board short-circuited by soldering.
• Indoor unit side
: Cut “R13” on the PC board.
(Each Operations Details)
EMERGENCY AND TEST OPERATION
Beep
Twice beep
<Remote control unit>
<Indoor unit>
Receive
Ex-factory setting (Mode A)
Ex-factory setting (Mode A)
Cut R13 on the PC board (Mode B)
Have "J1"on the PC
board short-circuited
by soldering (Mode B)
Receive
Not receive
Not receive
J1
Soldering
J1
Temperature
ABOVE 23
°
C
BELOW 23
°
C
COOLING
HEATING
26
°
C
23
°
C
CONTINUOUS
CONTINUOUS
AUTOMATIC
AUTOMATIC
Operation
mode
Designated
temperature
Timer mode
Air flow
HOW TO RELEASE EMERGENCY AND TEST OPERATION
INTERFERENCE PREVENTION OF SIGNALS FROM THE REMOTE CONTROLLERS
• In case of releasing during those operations, you can either push emergency operation switch once more or
apply operation using remote control.
You will hear a beep sound and emergency/ test operation is released.
• If you release the operation by remote control, operation will continue as setting of the remote control
automatically.