Toyotomi TAD-T40LW Скачать руководство пользователя страница 4

1

SUMMARY

The idea behind the unit is to provide a localized supply of cool air.

The unit will greatly enhance your personal comfort whether at a
work station or even in your favorite chair.

Four (4) casters enable you to move the unit easily from room to
room. It cools and dries the air at the same time so that you can
stay comfortable even when it's humid or rainy outside. Also your
furnishings and fabrics are kept in good condition when it's used
as dehumidifier.

Conventional air conditioners use large quantities of energy to cool
an entire room, including walls and furniture. This unit creates a
zone of cool and dry air only where it is needed. It does not waste
energy cooling the surroundings.

It's easy to operate. The built-in timer allows from 1 to 24 hours of
operation, which will automatically turn the unit on and off. This is
especially convenient at bedtime.

Venting is not required. However, if the unit is to be used exclu-
sively in one space, the cooling efficiency will be enhanced by us-
ing the venting kit accessory, which is included with the uit.

OPERATIONAL FEATURES

1.

COOLING OPERATION:

Normally, cool air is directed out the front louvers by the circu-
lation fan which has three (3) stages of fan speed.

2.

HEATING OPERATION:

Warm air is directed out the air outlet grille by the circulation
fan which has three (3) stages of fan speed.

3.

THERMO CONTROL

The compressor will automatically shift to ON or OFF to main-
tain the desired temperature.

4.

TIMER OPERATION:

The unit will turn on and off after the designated period of time
(1, 2, 3, ...24 hours).

5.

AUTOMATIC SHUT-OFF MECHANISM WHEN THE
DRAIN TANK IS FULL:

When the drain tank is full, the unit will be automatically shut
off. The warning lamp will light. It is always required to press
the power button twice to resume operation after the con-
densed water is removed from the tank.

6.

AIR FILTER:

A pre-filter protects the unit from dust.

1. DESCRIPTION

Fig. A

FRONT

A1

Air outlet

A2

Vertical louver

A3

Front panel

A4

Operation panel

A5

Carrying handle

A6

Caster

Fig. B

REAR

B1

Air intake (Evaporator)

B2

Air intake opening

B3

Air intake (Condenser)

B4

Power supply cord

B5

Power plug

B6

Drain water outlet

B7

Air outlet opening

Fig. C

OPERATION PANEL

C1

Power button

C2

Mode button

C3

Fan speed button

C4

Timer button

C5

Adjust buttons

C6

Warning lamp (Tank full)

C7

Cooling mode lamp (green)

C8

Dehumidifying mode lamp (orange)

C9

Heating/Fan mode lamp (red/yellow)

C10 Room temp lamp
C11 Set temp lamp
C12 Timer operation lamp
C13 Digital indicator

Fig. I

EXHAUST DUCT SET

I1

Exhaust duct hose adapter nozzle (4 pcs.)

I2

Exhaust duct hose (2 pcs.)

Fig. J

WINDOW PANEL KIT

J1

Window panel “C”

J2

Window panel extension (2 pcs.)

J3

Exhaust duct hose grille (2 pcs.)

J4

Cover (2 pcs.)

J5

Screws

2. SAFETY TIPS

IMPORTANT

¡

Read instructions carefully before operation.

¡

The unit should be operated when the room temperature is
between 64˚F (18˚C) to 95˚F (35˚C). If the room temperature is
below 64˚F (18˚C), ice may form on the coils. If the room tem-
perature is above 95˚F (35˚C), the compressor will automatical-
ly shut off to protect itself.

¡

ALWAYS, wait 3 min. to restart after turning unit off.

WARNING

¡

NEVER expose infants, handicapped persons, or senior per-
sons directly to the airflow. Adjust the airflow direction.

¡

Keep children away from unit. Children are particularly liable to
this danger. The inside fan is running at high speed. Covering
them may deteriorate air conditioner performance or cause it
to become inoperative.

¡

NEVER insert objects of any kind into the air intake or air out-
let.

¡

DO NOT unplug if your hands are wet. An electrical shock may
occur.

¡

DO NOT operate in a wet location.

¡

ALWAYS plug into 115 V, 60 Hz, single phase electrical outlet.

¡

Be sure the power plug fits the receptacle securely.

¡

DO NOT run power cord under carpets, rugs, or floor mats of
any kind.

¡

DO NOT attempt to shorten or alter power cord in any way.

¡

DO NOT apply any excessive force or pressure to the power
supply cord.

¡

Make sure that the plug is free of dust.

¡

DO NOT use an extension cord.

¡

DO NOT turn on and off by inserting or removing the power
plug which may cause electric shock or fire.

¡

If there is a fear of lightning, stop the unit and disconnect the
power supply cord.

¡

DO NOT touch the evaporator, condenser and pipes.

¡

DO NOT operate with filter removed. 

CAUTION

¡

Keep unit more than 20 in. (50 cm) away from any objects or
wall. (Fig. D)

¡

If the unit is operated in COOLING mode in an area of very
high moisture, the top plate and the rear plate may get cov-
ered with a mist. Wipe off any mist before it has a chance to
get on the floor or rug.

¡

Remove drain water before moving unit.

¡

To minimize corrosion, DO NOT use in damp, salty air area.

¡

DO NOT operate in direct sunlight.

¡

DO NOT use for such particular purpose as preservation of
foodstuff, animals, plants, precision appliances, arts and med-
icine.

¡

DO NOT place an animal, plants or combustion equipment in
a place which is subjected to the direct air flow of the unit.

¡

DO NOT ride or place the objects on the unit.

¡

DO NOT turn the unit on its side or upside down.

ENGLISH

 TAD-T40LW (GB/ES/FR)  12.5.14 10:48 AM   ページ 1

Содержание TAD-T40LW

Страница 1: ...LE AIR CONDITIONER ACONDICIONADOR DE AIRE PORTATIL CONDITIONNEUR D AIR DEPLACABLE INSTRUCTION MANUAL ENGLISH P 1 MANUAL DE INSTRUCCIONES ESPAÑOL P 5 MODE D EMPLOI FRANCAIS P 9 TAD T40LW GB ES FR 12 5 14 10 48 AM ページ b ...

Страница 2: ...t Temp Timer Operation High Med Low Fan Cooling Dehumidifying Heating B1 B7 B2 B3 B4 B6 B5 A1 A3 A6 A5 A4 A2 F1 C3 C1 C2 C5 C5 C4 C1 C2 C7 C8 C9 C6 C3 C5 C4 C11 C12 C13 C10 more than 20 in 50cm more than 20 in 50cm I1 I2 J3 J2 J1 J3 J4 J4 J5 J2 J5 TAD T40LW GB ES FR 12 5 14 10 48 AM ページ c ...

Страница 3: ...74 22740804 22740876 22740449 22740254 22740253 22740252 22740481 22740895 22740899 Base pan assembly Caster Float Micro switch Drain motor 4 way valve Compressor Rear fan motor Rear fan Capacitor A Rear FM Front fan motor Front fan Capacitor C Front FM Main circuit board CapacitorB Compressor Indication lamp circuit Front panel Power supply cord Drain cap Rear panel Intake air grille Thermistor R...

Страница 4: ... lamp C11 Set temp lamp C12 Timer operation lamp C13 Digital indicator Fig I EXHAUST DUCT SET I1 Exhaust duct hose adapter nozzle 4 pcs I2 Exhaust duct hose 2 pcs Fig J WINDOW PANEL KIT J1 Window panel C J2 Window panel extension 2 pcs J3 Exhaust duct hose grille 2 pcs J4 Cover 2 pcs J5 Screws 2 SAFETY TIPS IMPORTANT Read instructions carefully before operation The unit should be operated when the...

Страница 5: ...ress the fan speed button C3 to set the desired air flow rate High Operation at a high air flow Med Operation at a medium air flow Low Operation at a low air flow 5 AIR DEFLECTION Always open the air outlet during operation Fig E 6 STOP OPERATION Press the Power button C1 and all lights will go out TIMER OPERATION Auto turning OFF With unit in cooling mode press Timer button C4 to select number of...

Страница 6: ...3 ENGLISH A hissing noise or hollow sound A squeaking noise Odor The unit does not start nor change operation mode im mediately e This sound is generated from the refrigerant flowing within pipes e This noise is generated from the unit when it is expands or con tracts with temperature changes e Such odor as tobacco cosmetics or foods may accumulate in the unit e To prevent overloading the com pres...

Страница 7: ...s not extend to any defect due to the negli gence of others failure to install operate or maintain unit in ac cordance with instructions operating and maintenance instruc tions are furnished with each new unit unreasonable use acci dents alteration use of unauthorized or non standardized TOY OTOMI parts and accessories electrical malfunction i e as re sulting from large power surges short circuit ...

Страница 8: ...mer C13 Indicador digital Fig I JUEGO DEL CONDUCTO DE EVACUACION I1 Tobera del adaptador de la manguera del conducto de evacuación 4 pzas I2 Manguera del conducto de evacuación tubo flexible 2 pzas Fig J KIT DEL PANEL DE VENTANA DE PLASTICO J1 Panel de ventana C J2 Extensión del panel de ventana 2 pzas J3 Rejilla de la manguera del conducto de evacuación 2 pzas J4 Cubierta 2 pzas J5 Tornillos 2 IN...

Страница 9: ...peratura de la habitación 3 OPRIMA LOS BOTONES DE TIMER AJUSTE DE TEM PERATURA C5 Ajuste a la temperatura ambiente deseada presionando el botón UP o el botón DOWN La indicación por omisión es la temperatura de la habitación Cuando se oprime el botón o aparece la temperatura ajustada y puede ajustarlo Después de 15 segundos la indi cación volverá a la temperatura de la habitación Oprimiendo ambos b...

Страница 10: ... unidad trasera de escape la cual se 7 ESPAÑOL Silbido o ruido sordo Chirrido Olores La unidad no arranca ni cambia inmediatamente de modalidad de operación e Producido por el refrigerante cir culando dentro de los tubos e Producido por el acondicionador de aire debido a la expansión o contracción producida por los cambios de temperatura e El olor de los cigarrillos cosméticos o alimentos podría a...

Страница 11: ...IRE 8 ESPAÑOL GARANTIA LIMITADA TOYOTOMI CO LTD TOYOTOMI garantiza al comprador que este producto y sus correspondientes piezas están libres de defectos en material y mano de obra bajo empleo y servicio normales por un período de DOCE 12 MESES a partir de la fecha de la entrega al comprador original sujeto a los sigu ientes términos y condiciones Esta garantía cubre Al producto o cualquier pieza d...

Страница 12: ...cateur digital Fig I TUYAUTERIE D EVACUATION I1 Canule adaptatrice pour le tuyau de la gaine d évacuation 4 pièces I2 Tuyau d évacuation flexible 2 pièces Fig J KIT PANNEAU FENETRE J1 Panneau de la fenêtre C J2 Extension du panneau de la fenêtre 2 pièces J3 Grille du tuyau de la gaine d évacuation 2 pièces J4 Couvercle 2 pièces J5 Vis 2 CONSIGNES DE SECURITE IMPORTANT Lire soigneusement le mode d ...

Страница 13: ...ure de la pièce 3 APPUYEZ SUR LES BOUTONS DE REGLAGE MINUT ERIE TEMPERATURE C5 Veuillez régler la température désirée de la pièce en appuyant sur le bouton HAUT ou le bouton BAS L faffichage par défaut est la température de la pièce Lorsque le bouton ou est pressé la température réglée est affichée et peut être modifiée Après 15 secondes l faf fichage revient à celui de la température de la pièce ...

Страница 14: ...ctionnement immédiate ment e Ce bruit provient du liquide de re froidissement s écoulant dans les conduites e Ce bruit provient de l unité lors de dilatation ou de contraction avec les changements de température e Des substances telles que du tabac des produits cosmétiques ou des produits alimentaires peuvent s ac cumuler dans l unité e Pour empêcher toute surcharge du moteur du compresseur inter ...

Страница 15: ...euillez vous procurer le panneau fenêtre de rallonge B et l utiliser avec le panneau fenêtre C d origine Pièce 22740286 PANNEAU FENETRE DE RALLONGE B M 31 1 2 80 cm Pièce 22740288 PANNEAU FENETRE DE RALLONGE B L 56 142 cm Pièce 22740288 CANULE DE SORTIE D AIR 12 FRANCAIS GARANTIE LIMITEE TOYOTOMI CO LTD TOYOTOMI garantit tous ses produits et pièces en vente exempts de défauts matériels ou vices de...

Страница 16: ...Printed in China New 3 12 Part No 22740895 TOYOTOMI CO LTD 5 17 Momozono cho Mizuho ku Nagoya 467 0855 Japan www toyotomi jp TAD T40LW GB ES FR 12 5 14 10 48 AM ページ a ...

Отзывы: