background image

Installation of Floor And Ceiling Type Indoor Unit

3

Installation of Floor And Ceiling Type Indoor Unit

1  Space dimension for installation of the unit

The space around the unit is adequate for ventilation. (Refer to Fig.1)

Fig.1

2  Important notice

a.  The unit must be installed by the professional personnel according to this install instruction to ensure 

the well use. 

Please contact the local 

TOYOTOMI

 special nominated repair department before installation. Any malfunction 

caused by the unit that is installed by the department that is not special nominated by 

TOYOTOMI

 would not deal with 

on time by the inconvenience of the business contact.  

b.  It should be done by professional personnel when the air conditioner unit is moved to other place.

3  There are 2 styles of installation

Ceiling type

Floor type

Each type is similar to the other as follows:
a.  Determine the mounting position on ceiling or wall by using paper pattern to indicate indoor frame. 

Mark the pattern and pull out the paper pattern.(Refer to Fig.2) 

b.  Remove the return grill, the side panel and the hanger bracket from the indoor unit as per procedure 

bellow.

Press the fixing knob of the air intake grills, the grilles will be opened wider and then pull them out 

from the indoor.

Remove the side panel fixing screw and pull to the front direction (arrow direction) to remove. Side 

panel fixing screw. (Refer to Fig.3)

Содержание MUL-E12CFTA

Страница 1: ...A Multi VFR System Floor And Ceiling Type Indoor Unit For European Union This manual is suitable for the following models MUL E9CFTA MUL E12CFTA MUL E18CFTA MUL E24CFTA Please read this manual careful...

Страница 2: ......

Страница 3: ...to make the operation normal The cooling mode is not clash with the dry mode while the fan mode is not clash with any mode The appliance shall not be installed in the laundry The appliance shall not b...

Страница 4: ...e dimension for installation of the unit 3 2 Important notice 3 3 There are 2 styles of installation 3 4 Electrical wiring 6 5 Install the drainage pipe 7 6 Install the connection pipes 8 Constitutes...

Страница 5: ...le wire or adopts wires that are not recommend to use otherwise electric shock or fire may happened Please don t operate the unit by wet hand or electric shock may happened Don t insert finger or stic...

Страница 6: ...on Location Such a place where cool air can be distributed throughout the room Such a place where is condensation water is easily drained out Such a place that can handle the weight of indoor unit Suc...

Страница 7: ...th on time by the inconvenience of the business contact b It should be done by professional personnel when the air conditioner unit is moved to other place 3 There are 2 styles of installation Ceiling...

Страница 8: ...ide the arrowed position Refer to Fig 6 Suspension bolt stays inside the cap of indoor unit Never remove the cap e Lift the unit and slide forward unit the dent Refer to Fig 7 f Screw tightly both han...

Страница 9: ...bolt M8 Hanger bracket fixing bolt M6 Hanger bracket Fig 6 Fig 7 Fig 9 Fig 8 When installing the indoor unit you can refer the paper pattern for installation and make sure that the drainage side must...

Страница 10: ...om of the appliance upward then connect the brown wire to the Terminal board 3 black wire the communication wire to the Terminal board 2 blue wire to the Terminal board N 1 and connect the earthing wi...

Страница 11: ...ter than the diameter of the connecting pipe Keep the drain pipe short and incline downwards at a gradient of at least 1 100 to prevent air pockets Refer to Fig 10 Use the attached drain hose and clam...

Страница 12: ...pes Connect the connect pipe with the two relative leading pipe tie the nut on tie in of the connect pipe tightly Caution Be careful in bending the connection pipes or you will damage the pipes If the...

Страница 13: ...of Every Part of Floor And Ceiling Type Indoor Unit Surface Panel Connecting pipe Air outlet Air inlet Guide louver Air filter purifier in air inlet grille Suitable model MUL E9CFTA MUL E12CFTA MUL E...

Страница 14: ...rking Temperature Range Indoor side state Outdoor side state Dry bulb temp Wet bulb temp Dry bulb temp Wet bulb temp Rated Cooling 27 19 35 24 Max cooling 32 23 48 26 Min cooling 21 15 18 Rated Heatin...

Страница 15: ...eaning the unit Clean the air conditioner and the remote control with dry cloth or a vacuum cleaner If damp cloth is used remove moisture by using dry cloth afterward Caution Do not use benzene gasoli...

Страница 16: ...cool air Clean the air filter every week for higher efficiency by professional Close window and door while operating the unit to prevent leakage of cooled air and save energy Draw close curtains or cl...

Страница 17: ...done by professional Do not use pieces of wire instead of fuse Do not insert objects into the air inlet or outlet when the air conditioner is running as it may cause damage or personal injury Also pa...

Страница 18: ...by professional The cooling heating effect of the air conditioner is not good Is the temp set in proper Is the inlet outlet vent of outdoor unit blocked Is the air filter too dirty to cause blockage A...

Страница 19: ......

Страница 20: ......