22
S E R V I C E
M A N U A L
L A S E R H E A T I N G S Y S T E M S
L A S E R H E A T I N G S Y S T E M S
Trouble Shooting
Section 4
No
Item
Specification
Conditions
Remarks
1
17 Set OK timing
(T22)
10 ± 2 sec.
Set room temperature
18 Fuel recovery timing (T23)
Within 3 sec.
19 Burner thermistor
low temperature timing (T25)
3±2 sec.
20 Burner thermistor timing
(T26)
300 ± 30 sec.
21 False flame detection timing
(T44)
30 ± 2 sec.
22 Low voltage timing
(T46)
10 ± 2 sec.
2
Flame detector
Measurement meter: Yokogawa 2011-SB2 (class 1,
range of 3
A)
When no flame is detected during miss ignition timing
(T12), display E- 2.
When miss ignition is detected 3 times in succession,
display E- 22.
When no flame is detected during combustion, shift
to extinguishing process and stop operation.
Only when the detection current exceeds 0.6
A
1 Detection current
More than 0.6
A
(recommended value
is 0.3
A)
2 Allowable leakage
resistance
More than 1.5 M
3
Room thermistor
Thermistor used is B constant 4100; resistance at 25
deg. C is 10 K
.
1 Maximum set temperature
32.7 ± 2.3
℃
Shall display 90 deg. F
2 Minimum set temperature
10.4 ± 2.0
℃
Shall display 50 deg. F
3 Differential 1
1.0 ± 0.5deg
Normal combustion
Maximum temperature
setting
Set temperature: 90 deg. F
Minimum temperature setting
Set temperature: 50 deg. F
4 Differential 2
2.0 ± 0.7deg
Flame extinguishing
Maximum temperature
setting
Set temperature: 90 deg. F
Minimum temperature setting
Set temperature: 50 deg. F
7.08 K
+0.74
0.68
20.34 K
+2.18
1.92
0.24 K
+0.11
0.12
1.01 K
+0.32
0.33
0.58 K
+0.22
0.33
3.28 K
+1.19
1.25
S5566N 4.7M
4-2
Control Circuit Board
Time Chart