S E R V I C E
M A N U A L
9
L A S E R H E A T I N G S Y S T E M S
2-1
Introductlon
Heater maintenance is divided into two classifications;
routine maintenance, which is required to keep the
heater in good operating condition; and corrective
maintenance, which is necessary in repairing any
malfunctions.
2-2
Routine Maintenance
The maintenance schedule provided in Table 4-1
describes the tasks that must be performed periodically
for optimum heater performance.
At the time of the demonstration or installation, heater
maintenance should be discussed with the user;
emphasize that a clean heater and proper fuel are the
keys to optimum heater operation and performance.
CAUTION:
Be sure to unplug the heater before
checking or cleaning the unit.
CAUTION:
Allow the heater to cool completely
before cleaning or maintaining.
Routine Maintenance
Section 2
Table 2-1 SUGGESTED ROUTINE MAINTENANCE
ACTIVITY
MATERIAL
REMARKS
Check all fuel lines for leaks and
/ or
loose connections.
3/8" (9.52 mm) OD copper
tubing
Fuel lines must be secure and free of
leaks. Replace tubing if necessary.
Inspect exhaust lines for leaks
and/
or
loose connections.
All exhaust pipes must be covered by an
insulating cloth cover.
Check fuel for water and/or other
contamination.
If the removable fuel tank is used for
Laser 560,
the
tank filter should be
checked, cleaned or replaced.
Also, make sure that the fuel supply hose
is tightly connected to both the removable
fuel tank and the fuel sump.
Fuel filter or water block filter on the fuel
line is recommended.
Fuel color should be crystal clear.
If fuel is contaminated, see corrective
maintenance procedure, paragraph 4-7.
Inspect the fuel pipe for obstruction.
The piping should be free of sharp bends
or obstrustions. Air locks could block the
fuel supply.
Inspect the electrical wiring for cracks,
signs of deterioration, bare wires and/
or loose connect
ion
s.
Clean the front panel louvers.
(once a week)
Use a clean, Iint-free cloth
and a non-abrasive household
cleaning agent. USE ONLY
NON-PETROLEUM DISTILLATE
CLEANERS.
Wipe off louvers.
Vacuum inside of heater if necessary.
Clean the room air circulation fan.
(once a week)
Vacuum filter cover. Wipe off fan blades.
Check the flue pipe area.
(once a week)
Check the flue pipe joint to make sure
connection is firm. Use a vacuum cleaner
to remove any dust or pet hair.
Also make sure that the top flue pipe
is
not covered by any obstacles.
Clean fuel inlet strainer of fuel sump.
(once a week)
Refer to paragraph 4-5.