P25589
ST--12
--
STARTING
STARTER
6 . CLE AN CO NTACT S URFACE S O F CO NTACT P L AT E
AND P L UNG E R
Clean the contact surfaces of the remaining contact plate and
plunger with a dry shop rag.
7 . RE I NS TALL MAG NE TI C S WI TCH E ND CO V E R
Install the plunger, new gasket, end cover and lead clamp (1.0
kW, 2.0 kW type:) with the 3 bolts.
Torque:
1.2 kW, 1.4 kW type: 2.5 N
∙
m (26 kgf
∙
cm, 23 in.
∙
lbf)
1.0 kW, 2.0 kW type: 3.6 N
∙
m (37 kgf
∙
cm, 32 in.
∙
lbf)