8.8

Adjusting the return stroke lock (optional)

NOTE! 

Do not push the hand lever back while the mechanism is locked. 

1

2

6

3

5

4

1

Threaded hole (position 1)

2

Cheese head screw (position
2)

3

Cross bore hole

4

Unlocking device

5

Inner mechanism

6

Cheese head screws

Содержание FinePress KFL

Страница 1: ...Original operating instructions TOX FinePress KFS KFL KFW TOX PRESSOTECHNIK Riedstrasse 4 D 88250 Weingarten www tox pressotechnik com Edition 09 01 2020 Version 1 GmbH Co KG ...

Страница 2: ...2 TOX_Manual_FinePress_KFS KFL KFW_en ...

Страница 3: ...f general notes 10 1 6 3 Highlighting of texts and images 10 1 7 Contact and source of supply 11 2 Safety 2 1 Basic safety requirements 13 2 2 Organizational measures 13 2 2 1 Safety requirements for the operating company 13 2 2 2 Selection and qualifications of personnel 14 2 3 Fundamental hazard potential 15 2 3 1 Electrical hazards 15 2 3 2 Thermal hazards 15 2 3 3 Pneumatic hazards 15 2 3 4 Co...

Страница 4: ... Safety during transport 25 5 2 Storage when not in use 26 5 3 Transport by lifting device 27 5 4 Dispatch for repair 28 6 Installation 6 1 Safety during installation 29 6 2 Requirements for installation 30 6 2 1 Set up location 30 6 3 Installing accessories 31 6 3 1 Installing process monitoring option 31 6 3 2 Installing the ergonomic handle optional 32 6 3 3 Installing the stroke counter option...

Страница 5: ...the toggle lever on presses with set screws 50 8 6 Fine adjustment of working stroke option 51 8 7 Resetting the stroke counter optional 51 8 8 Adjusting the return stroke lock optional 52 8 9 Setting the travel sensor option 55 9 Troubleshooting 9 1 Safety during troubleshooting 57 9 2 Detecting faults 58 Maintenance table 10 Maintenance 10 1 Safety during maintenance 61 10 2 Requirements for mai...

Страница 6: ...s 11 1 Safety and repairs 65 12 Disassembly and Disposal 12 1 Safety during disassembly and disposal 67 12 2 Decommissioning 68 12 3 Shutdown 68 12 4 Disassembling 69 12 5 Disposal 69 13 Appendices 13 1 Declaration of conformity 71 13 2 Press force diagrams 75 Index ...

Страница 7: ...ation of trademarked brands that do not belong to TOX PRESSOTECHNIK are for information only all rights remain the property of the owner of the trademarked brand Operating instructions manuals technical descriptions and software are originally compiled in German 1 2 Exclusion of liability TOX PRESSOTECHNIK has checked the contents of this publication to ensure that it conforms to the technical pro...

Страница 8: ...ments In addition to the available manual further documents can be supplied These documents must also be complied with Other applicable documents can be for example additional operating manuals e g of components or of a whole sys tem Supplier documentation Instructions such as software manual etc Technical data sheet Safety data sheets Data sheets 1 5 Gender note In order to enhance readability re...

Страница 9: ... are not taken è Measures for remedial action and protection WARNING Identifies a potentially dangerous situation Death or serious injury may occur if appropriate safety measures are not taken è Measures for remedial action and protection CAUTION Identifies a potentially dangerous situation Injury may occur if appropriate safety measures are not taken è Measures for remedial action and protection ...

Страница 10: ...d to ensure trouble free operation w Identifies the result of an action u Identifies the result of a complete action è Identifies a single action step or several action steps that are not in an operating sequence The highlighting of operating elements and software objects in texts facili tates distinction and orientation In square brackets identifies operating elements such as buttons levers and v...

Страница 11: ...ct and source of supply Only use original spare parts or spare parts approved by TOX PRES SOTECHNIK TOX PRESSOTECHNIK GmbH Co KG Riedstraße 4 D 88250 Weingarten Tel 49 0 751 5007 333 E Mail info tox de com For additional information and forms see www tox pressotechnik com ...

Страница 12: ...Important information 12 TOX_Manual_FinePress_KFS KFL KFW_en ...

Страница 13: ...pliance with the following safety requirements The operating manual must always be kept available at the operation site of the product Ensure that the information is always complete and in legible form In addition to the operating manual the generally valid legal and other binding rules and regulations must be provided for the following content and all personnel must be trained accordingly Work sa...

Страница 14: ...ppoint persons to work on the plant who have read and under stood the operating manual and in particular the safety instructions before starting work This is particularly important for persons who only work on the plant occasionally e g for maintenance work Only allow persons appointed and authorized for this work access to the plant Only appoint reliable and trained or instructed personnel Only a...

Страница 15: ...ys keep the control box and or terminal box closed Before commencing work on electrical equipment switch off the main switch of the system and secure it against being switched back on in advertently Pay attention to the dissipation of residual energy from the control sys tem of the servomotors Make sure that the components are disconnected from the power sup ply when carrying out the work 2 3 2 Th...

Страница 16: ...parts or tools cannot fall down or descend as a result of stored energy Use appropriate fuses 2 3 5 Hydraulic hazards Attention must be paid to hydraulic hazards particularly on the supply lines connection points and vent points The following applies generally Allow work to be carried out on hydraulic equipment by authorized ser vice personnel only Wear individual protective equipment Do not excee...

Страница 17: ...g chemical sub stances Observe the applicable safety regulations on handling chemical sub stances and the information on the manufacturer s safety data sheets of hazardous substances Wear individual protective equipment In the event of eye or skin contact rinse the affected area change con taminated clothing and visit a doctor if necessary Provide appropriate equipment eye wash bottle washbasin ne...

Страница 18: ...ous injuries The following safety symbols can be attached on the product Symbol Hazard Notes Warning of suspended load Do not stay in the danger zone of the suspended load Identifies fork lift truck brackets Identifies attachment point Warning of hot surfaces In the area of motors drives and fans Warning of electrical voltage In the area of the entire control box Warning of crushing Risk of crushi...

Страница 19: ...es 3 1 1 Safe and correct operation Intended use includes the following conduct Only operate with the components for which it is specified Follow all instructions in this operating manual Comply with the specified maintenance intervals and perform mainte nance work correctly Operate in compliance with the conditions of the technical data Operation with fully assembled and functional safety devices...

Страница 20: ...correct parameterization Execution of activities by persons who are not qualified or authorized to do so The operating company is exclusively responsible for all personal injury and property damage resulting from non intended use Non intended use will not be covered by the warranty or the operating approval 3 1 3 Substances harmful to the wetting properties of lacquers LABS No substances containin...

Страница 21: ...th little effort at the lever 6 5 4 3 2 1 Fig 1 Product overview Designation Function 1 Hand lever Drives the ram onto the workpiece 2 Ram guide Guides and lubricates the ram 3 Ram Transfers the force to the workpiece 4 Height adjustment scale Facilitates the adjustment of the open height 5 Press bed With T groove for taking up tools 6 Fastening holes For screw fitting to the floor ...

Страница 22: ...About this product 22 TOX_Manual_FinePress_KFS KFL KFW_en ...

Страница 23: ..._KFS KFL KFW_en 23 4 Technical data 4 1 Type sheet and data sheet For technical data and installation dimensions see type sheet and data https www tox pressotechnik com 4 2 Press force diagrams See Chap 13 2 Press force diagrams Page 75 ...

Страница 24: ...Technical data 24 TOX_Manual_FinePress_KFS KFL KFW_en ...

Страница 25: ...sporting and setting down make sure that no parts of the body become jammed è Wear suitable personal protective equipment e g safety boots CAUTION Injury from toppling and falling products è Secure product from toppling falling accidentally moving è Store product horizontally or secure with dowels The transportation may only be carried out by authorized personnel The product may only be transporte...

Страница 26: ...roducts è Secure product from toppling falling accidentally moving è Store product horizontally or secure with dowels The following applies Do not store the product outdoors Protect the product against the influence of the weather Avoid temperature fluctuations so as to prevent corrosion from con densation Seal connection openings ...

Страница 27: ...ifting device A threaded bore hole is provided for a ring bolt for lifting the TOX Fine Press 2 1 1 Threaded hole 2 Cover 1 Remove the cover from the press frame 2 Remove the crank ring bolt and other loose parts from the TOX Fine Press 3 Screw the ring bolt into the threaded bore ...

Страница 28: ...panying repair form This we supply in the service sector on our website or upon request via e mail Send us the completed form via e mail Then you will receive the shipping documents from us via e mail Send us the product with the shipping documents and a copy of the Accompanying repair form For contact data see Chap 1 7 Contact and source of supply Page 11or www tox pressotechnik com ...

Страница 29: ...conducting lines Serious injuries to eyes and body cavities è Always connect and disconnect lines without pressure è Pay attention to maximum permitted pressures è Wear individual protective equipment WARNING Hazard from suspended loads Severe crushing impacts and serious accidents as a result of improper transportation and falling load è Only use lifting gear that is appropriate and in perfect te...

Страница 30: ... KFL KFW_en 6 2 Requirements for installation 6 2 1 Set up location The set up location Must be free from dust and dirt Must be a closed room Must have a firm level floor The stability must be ensured The product must be screwed to the floor ...

Страница 31: ...tion TOX_Manual_FinePress_KFS KFL KFW_en 31 6 3 Installing accessories 6 3 1 Installing process monitoring option è Please see the separate operating manual for the installation of the process monitoring system ...

Страница 32: ...onomic handle optional 2 1 3 1 Additional handle 2 Handle 3 Clamp screw 1 Unscrew the handle of the hand lever 2 Slide the ergonomic handle onto the hand lever 3 Screw the additional handle in the desired position with the clamping screw 4 Reattach the handle of the hand lever ...

Страница 33: ...ptional 2 1 1 Cable set 2 Counter housing 1 Disconnect the cable set from the counter housing 2 Install the counter housing on the press head using cylinder screw M 5x12 3 Loosen the toggle lever from the lever head and tilt it to the front See Chap 8 5 Adjusting the working stroke Page 48 ...

Страница 34: ...t of the push button The push button must switch shortly before reaching the final position The switching point is set using the two nuts on the push button 4 Connect the cable set to the counter housing 5 Connect the toggle lever and lever head using stud See Adjusting the working stroke Page 48 6 When assembling the stud must be fastened in the same bore hole of the lever head Otherwise the pres...

Страница 35: ...fixing device 6 Clamp 7 Straight connector 8 Fixing device 1 Screw the fixing device onto the press head 2 Screw the force sensor onto the ram 3 Fasten the cable clamp with the screw 4 Connect the angled plug to the force sensor 5 Screw the clamp in the lowest position onto the fixing device 6 Connect the straight connector to the evaluation unit and insert it into the clamp ...

Страница 36: ...Installation 36 TOX_Manual_FinePress_KFS KFL KFW_en F2 F2 F1 F1 è NOTE Observe the maximum thread length The tool must bear against flange 1 or flange 2 ...

Страница 37: ...eturn stroke lock option During retrofitting it may be necessary to replace the shaft In this case please contact TOX PRESSOTECHNIK 1 2 3 1 Lever shaft 2 Cover 3 Cheese head screws M5 x 16 1 Unscrew the lever shaft from the cover The flat spiral spring must nor be removed ...

Страница 38: ... return stroke lock on the lever shaft and screw it on with the M 5x16 cylinder screws 3 The unlocking button must point to the front and be positioned on STOP 4 Insert the cam disc into the housing The cam disk must latch in on the lever shaft 5 Fix the lock washer with the M 6x12 locking screw 6 The return stroke lock must be adjusted See Adjusting the return stroke lock Page 52 7 Install the ho...

Страница 39: ...g holes 7 Fastening groove T groove 8 Retract pneumatic connection 9 Pneumatic the cylinder op tional 10 Extend pneumatic connection 1 Insert the T groove nuts into the fastening groove of the press frame 2 Pull out the tool plate until the fastening holes are accessible 3 Screw the base plate over the mounting holes using the T groove nuts 4 The insertion width is set via the stop ...

Страница 40: ...g 6 Fixing device 7 Counter nuts 1 Unscrew the product tag 2 Screw on the fixing device together with the tag The travel sensor is pointing towards the press frame 3 Screw the rear fixing device onto the press head 4 Connect the cable to the evaluation unit 5 Screw the straight connector to the fixing device using the fastening clip 6 Set the zero point see Setting the travel sensor Page 55 ...

Страница 41: ...S KFL KFW_en 41 6 3 8 Installing the tool holding fixture optional 2 1 1 Ram 2 Tool holding fixture è The tool holding fixture is screwed into the ram For technical data and installation dimensions see data sheet www tox pressotechnik com ...

Страница 42: ...Installation 42 TOX_Manual_FinePress_KFS KFL KFW_en ...

Страница 43: ...s_KFS KFL KFW_en 43 7 Commissioning 7 1 Safety during the commissioning The system may only be commissioned by trained and authorized service personnel 7 1 1 Safety device All safety equipment must be properly assembled and functional ...

Страница 44: ... locks are removed Supply connections communication and control connections material or media hoses are installed properly The permissible values are com plied with The necessary software for controlling the component is installed TOX PRESSOTECHNIK has released the system and associated components for commissioning No tools installation equipment or other interfering objects may be left in the too...

Страница 45: ... entire system are properly assembled and functional All piece parts are intact and properly maintained Supply connections communication and control connections material or media hoses are installed properly The permissible values are com plied with The main switches of the system or component are switched on The fault messages on the system or component are acknowledged 8 3 Process monitoring See...

Страница 46: ...nual_FinePress_KFS KFL KFW_en 8 4 Setting the open height of the press head 4 3 2 1 1 Fastening screws 2 Square 3 Crank 4 Cover NOTE Damage on the tool or the workpiece Calculate the open height be fore starting operation ...

Страница 47: ...nscrew the screws 3 Place the supplied crank onto the square and adjust the open height by turning it Turning clockwise increases the open height Turning anti clockwise reduces the open height 4 Remove the crank and stow it away 5 Tighten the fastening screws of the clamping plate Observe the tight ening torques see Inspecting the fastening of the press head Page 63 6 NOTE Damage on the tool The t...

Страница 48: ...ting the working stroke The working stroke of the press can be changed by shifting the toggle lever The force stroke ranges can be found in the data sheet If a travel sensor is installed it must then be readjusted See Chap 8 9 Ad justing travel sensor Page 55 ...

Страница 49: ... a bracket 2 3 1 4 1 Screws 2 Bracket 3 Toggle lever 4 Stud 1 Unscrew the screws and remove the bracket 2 Remove the studs w The toggle lever is loosened 3 Move the toggle lever into the desired position 4 Install the studs 5 Install the bracket to secure the studs w The toggle lever is connected ...

Страница 50: ... 2 Rear bore holes for set screws 3 Set screws 4 Lever head 5 Stud 1 Unscrew and remove the set screws 2 Pull out of the stud w The toggle lever is loosened 3 Move the toggle lever into the desired position 4 Install the studs 5 Screw the set screws into the corresponding bore hole to secure the stud w The toggle lever is connected ...

Страница 51: ...the adjusting ring to adjust the open height A line on the scale of the adjusting ring corresponds to a height adjust ment of 0 02 mm Turning clockwise increases the open height Turning anticlockwise reduces the open height 3 Fix the adjusting ring with the clamping screw 8 7 Resetting the stroke counter optional The stroke counter has a reset button è Press the stroke counter button ...

Страница 52: ...Adjusting the return stroke lock optional NOTE Do not push the hand lever back while the mechanism is locked 1 2 6 3 5 4 1 Threaded hole position 1 2 Cheese head screw position 2 3 Cross bore hole 4 Unlocking device 5 Inner mechanism 6 Cheese head screws ...

Страница 53: ... return stroke lock un locks The lock engages twice audibly with a click and unlocks by turn ing it further A suitable tool e g Allen key can be inserted into the cross bore hole to turn the mechanism 5 Tighten the cheese head screws positions 2 and 6 6 Install the housing cover Lever travel for position 1 4 0 2 4 2 4 1 7 3 2 1 4 1 Maximum lever opening OT 2 Return stroke activates return stroke l...

Страница 54: ... Install the housing cover Lever travel for position 2 4 9 4 2 1 7 1 2 3 4 1 Return stroke activates return stroke lock 2 The return stroke lock engages during forward stroke 3 The return stroke lock engages during forward stroke 4 Forward stroke unlocks return stroke lock UT ü The return stroke lock has engaged ü The housing cover is removed 1 Unscrew the cheese head screw position 1 and screw it...

Страница 55: ...he travel sensor option 1 1 Counter nuts of travel sensor 1 Loosen the counter nuts of travel sensor 2 Press the hand lever of the press firmly up and hold 3 Set the zero point on the travel sensor by turning the nut 4 Tighten the counter nuts of the travel sensor ...

Страница 56: ...Operation 56 TOX_Manual_FinePress_KFS KFL KFW_en ...

Страница 57: ...KFS KFL KFW_en 57 9 Troubleshooting 9 1 Safety during troubleshooting Faults may only eliminated by trained and authorized service personnel The following applies Inform operating personnel before starting repair work Appoint a supervisor ...

Страница 58: ...bed Fault Cause Measures The ram does not ex tend There is a mechanical fault on the guide Contact authorized service personnel The nominal force not reached There is a mechanical fault on the guide Contact authorized service personnel The press head is not adequately fastened Tighten the fastening screws evenly Observe the tightening torques see Inspecting the fas tening of the press head Page 63...

Страница 59: ...n the area of application the actual values may differ from the guide values The ac tual intervals can be found in the system control Maintenance cycle Additional information Weekly 10 3 1 TOX FinePress inspecting Monthly 10 3 3 Inspecting and cleaning movable parts and guides Half yearly 10 3 2 Inspecting the fastening of the press head ...

Страница 60: ...Maintenance table 60 TOX_Manual_FinePress_KFS KFL KFW_en ...

Страница 61: ...e maintenance intervals may have to be verified with the manufac turer if necessary Perform only maintenance work that is described in this manual Inform operating personnel before starting repair work Appoint a supervisor 10 2 Requirements for maintenance 10 2 1 Set system to maintenance position Unless specified otherwise before all maintenance work 1 Retract the working piston w Plant is in hom...

Страница 62: ...nePress inspecting ü System is in maintenance position See Set system to maintenance position Page 61 1 Check the plant particularly moving parts for obvious defects and dam age 2 Check all parts inside and outside for wear obvious defects and dam age 3 Check the supply connections for tightness ...

Страница 63: ... ü System is in maintenance position See Set system to maintenance position Page 61 1 Check the tightening torque of the fastening screws 2 NOTE Damage on the tool Check the alignment of the tool Screw size Tightening torque M 8 30 Nm M 10 80 Nm M 12 135 Nm M 16 340 Nm Tab 2 Fastening screws of the press head on the frame ...

Страница 64: ... Only touch bare areas with gloves è Use cleaning set such as industrial cleaner e g Loctite 7063 or Würth Montagekraftreiniger 0890 107 vacuum cleaner dry cloth and brush è Do not clean with compressed air but with suction è After cleaning protect bare outer surfaces from corrosion Coat sur faces with a cloth slightly moistened with anticorrosive fluid è Keep inside surfaces especially element ca...

Страница 65: ...Repairs TOX_Manual_FinePress_KFS KFL KFW_en 65 11 Repairs 11 1 Safety and repairs The system may only be repaired by trained and authorized service person nel ...

Страница 66: ...Repairs 66 TOX_Manual_FinePress_KFS KFL KFW_en ...

Страница 67: ...ect power supply è Wait for residual energy to disspate safely at least 3 minutes WARNING Ejecting parts and compressed air from compressed air conducting lines Serious injuries to eyes and body cavities è Always connect and disconnect lines without pressure è Pay attention to maximum permitted pressures è Wear individual protective equipment CAUTION Sharp edges caused by material splintering Inju...

Страница 68: ... that the system is shut down permanently and or is pre pared for removal 1 Stop system and wait for it to come to a standstill 2 Remove material if necessary 3 Switch off the system at the main switch and secure it against being switched on again 4 First disassemble or dismantle after switching off the power electricity pneumatics and after residual energy has safely dissipated at least 3 minutes...

Страница 69: ...d properly è Regional disposal regulations must be observed 1 Strip the system down into its constituent parts 2 Dispose of greases and oils separately 3 Sort the constituent parts by material and dispose of according to the local regulations 12 5 Disposal When disposing of packaging consumables and spare parts including the machine and its accessories the relevant national environmental protectio...

Страница 70: ...Disassembly and Disposal 70 TOX_Manual_FinePress_KFS KFL KFW_en ...

Страница 71: ...Appendices TOX_Manual_FinePress_KFS KFL KFW_en 71 13 Appendices 13 1 Declaration of conformity ...

Страница 72: ...Appendices 72 TOX_Manual_FinePress_KFS KFL KFW_en ...

Страница 73: ......

Страница 74: ......

Страница 75: ...Appendices TOX_Manual_FinePress_KFS KFL KFW_en 75 13 2 Press force diagrams ...

Страница 76: ... you will find the notice to the deflection in the technical data of the operating instructions TOX Pressotechnik Riedstraße 4 D 88250 Weingarten Tel 0751 5007 0 Fax 0751 52391 E Mail info tox de com 0 0 0 2 0 4 0 6 0 8 1 0 1 2 1 4 1 6 1 8 2 0 2 2 2 4 2 6 2 8 3 0 3 2 3 4 3 6 3 8 4 0 Hub vor Strecklage des Kniehebels mm Stroke before full toggle extension mm Presskraft N Pressforce N KFS 002 002 2 ...

Страница 77: ...straße 4 D 88250 Weingarten Tel 0751 5007 0 Fax 0751 52391 E Mail info tox de com 0 0 0 4 0 8 1 2 1 6 2 0 2 4 2 8 3 2 3 6 4 0 Hub vor Strecklage des Kniehebels mm Stroke before full toggle extension mm Presskraft N Pressforce N KFSU LU WU 008 002 4 kN Presskraftdiagramm Press force diagram 220 N 160 N 100 N 40 N Belastungsgrenze limit Handhebelkraft lever force 0 0 0 4 0 8 1 2 1 6 2 0 2 4 2 8 3 2 ...

Страница 78: ...traße 4 D 88250 Weingarten Tel 0751 5007 0 Fax 0751 52391 E Mail info tox de com 0 0 0 4 0 8 1 2 1 6 2 0 2 4 2 8 3 2 3 6 4 0 Hub vor Strecklage des Kniehebels mm Stroke before full toggle extension mm Presskraft N Pressforce N KFSU LU WU 016 002 8 kN Presskraftdiagramm Press force diagram 220 N 160 N 100 N 40 N Belastungsgrenze limit Handhebelkraft lever force 0 0 0 4 0 8 1 2 1 6 2 0 2 4 2 8 3 2 3...

Страница 79: ...traße 4 D 88250 Weingarten Tel 0751 5007 0 Fax 0751 52391 E Mail info tox de com 0 0 0 4 0 8 1 2 1 6 2 0 2 4 2 8 3 2 3 6 4 0 Hub vor Strecklage des Kniehebels mm Stroke before full toggle extension mm Presskraft N Pressforce N KFSU LU WU 025 004 16 kN Presskraftdiagramm Press force diagram 220 N 160 N 100 N 40 N Belastungsgrenze limit Handhebelkraft lever force 0 0 0 4 0 8 1 2 1 6 2 0 2 4 2 8 3 2 ...

Страница 80: ...eitung you will find the notice to the deflection in the technical data of the operating instructions TOX Pressotechnik Riedstraße 4 D 88250 Weingarten Tel 0751 5007 0 Fax 0751 52391 E Mail info tox de com 0 0 2 0 4 0 6 0 8 1 1 2 1 4 1 6 1 8 2 2 2 2 4 2 6 2 8 3 3 2 3 4 3 6 3 8 4 Hub vor Strecklage des Kniehebels mm Stroke before full toggle extension mm Presskraft N Pressforce N KFS L W 025 005 25...

Страница 81: ...anleitung you will find the notice to the deflection in the technical data of the operating instructions TOX Pressotechnik Riedstraße 4 D 88250 Weingarten Tel 0751 5007 0 Fax 0751 52391 E Mail info tox de com 0 0 2 0 4 0 6 0 8 1 1 2 1 4 1 6 1 8 2 2 2 2 4 2 6 2 8 3 3 2 3 4 3 6 3 8 4 Hub vor Strecklage des Kniehebels mm Stroke before full toggle extension mm Presskraft N Pressforce N KFS L W 033 002...

Страница 82: ...Index 82 TOX_Manual_FinePress_KFS KFL KFW_en ...

Страница 83: ...spatch Repair 28 Disposal 67 69 Safety 67 Document additional 8 Validity 8 Drive Fastening Inspecting 63 E Electromagnetic Hazard 16 Ergonomic handle Installing 32 Exclusion of liability 7 F Faults Detect 58 Fine adjustment Working stroke 51 FinePress Inspecting 62 Maintaining 62 Force sensor Installing 35 Function description 21 G Gender note 8 Guidelines 7 Guides Inspecting 64 H Hazard Contusion...

Страница 84: ...note 7 M Maintenance 61 FinePress 62 Requirement 61 Safety 61 Maintenance position 61 Measures Organizational 13 Misuse 20 Mounting Travel sensor 40 N Noise Hazard 17 Note Gender 8 General 10 Legal 7 Warning signs 9 O Open height of the press head Setting 46 Operation 45 Process monitoring 45 Requirements 45 Safe 19 Safety 45 Organizational measures 13 P Press force diagrams 23 Process monitoring ...

Страница 85: ... Travel sensor 55 Set up location 30 Shift toggle lever Bracket 49 Set screws 50 Shutdown 68 Slide table Installing 39 Source of supply 11 Storage 25 26 Stroke counter Installing 33 Resetting 51 Substances harmful to the wetting properties of lacquers LABS 20 T Target group 8 Technical data 23 Texts Highlighting 10 Tool holding fixture Installing 41 Transport 25 Attachment point 27 Safety 25 Trave...

Страница 86: ...Index 86 TOX_Manual_FinePress_KFS KFL KFW_en ...

Отзывы: