YW1838
8
Penalty Time (Keypad Anti-Tamper Lockout Time)
Adjust Penalty Time
Key Sequence
[#] [Master Code] ● [92] ● [1-digit invalid codes entry] ● [1-digit X0 seconds] ●●
•
For example,
to adjust Penalty Time for 70 seconds after 5 invalid entries, press
[#] [5555] ● [92] ● [5] ● [7] ●●
Disable Penalty Time
Key Sequence
[#] [Master Code] ● [92] ● [0] ● [0] ●●
•
Number of invalid User Codes can be programmed from 0 (disable) to 9.
•
Penalty Time can be programmed from 10 seconds to 90 seconds, incremental in 10s (i.e. 9 = 90 seconds).
Identify User ID
Key Sequence
[#]
[Master Code] ● [09] ● [Enter Code to be located] ●●
If the code entered is recognized, the following sequence will occur:
•
At the start of the Code Location Function, the lock will flash both the green and red LEDs and emit 2 beeps.
•
The lock will identify the first digit by flashing the green LED and beeping 0
– 9 times.
•
To signify the end of the first digit sequence, the lock will flash both the green and red LEDs and will emit 2 beeps.
•
The lock will identify the second digit by flashing the green LED and beeping 0
– 9 times.
•
To signify the end of the second digit sequence, the lock will flash both the green and red LEDs and will emit 2 beeps.
Should the code not be recognized, the lock will sound one long beep (0.5 sec) with a red LED.
Содержание e-Smart 2000 Series
Страница 1: ...YW1838 0 ...
Страница 12: ...YW1838 11 ...