TCWS.54NGST04D_120517-20
5056.425183D
Accessing the gas valve for conversion
1. If installed, remove the burner media (rocks, glass, etc.) from the burner tray. Remove the edge
panels, burner tray, left hand burner, left hand side panel, release pilot assembly from center leg
and remove left hand secondary floor panel.
2. Remove large cover panel. If this fireplace has lighting built in to the secondary floor, it will be
necessary to disconnect the lighting wires from the electrical connection compartment in front
of the control box in order to withdraw the lighting wires through the grommet (Figure 41). Make
sure that the power is turned off at the breaker box.
Grommet
Figure 41: Wires through grommet.
Figure 42: Large cover removed.
14