6. Remove the electrical connection compartment cover and feed all four lights wires through the opening.
The lights wiring will connect to the wiring that supplies the fire place power (Figure 7).
7. Connect the wires to a switched 120 VAC, 60Hz, 3A power supply, one pair made up of one wire from the
left and one wire from the right light set to the “HOT” incoming line. The remaining pair to the “Neutral”
incoming line. See “Lights Wiring Diagram” on page 22. Reinstall the electrical connection compart-
ment cover.
8. Return to the firebox and secure the two secondary floor panels with four T20 screws for each of the two
panels.
9. From the REAR of the fireplace, position one of the two burners on an angle and attach the pilot assembly
to the burner leg using two Robertson screws provided (Figure 8). Note that the pilot will be positioned on
an angle.
Figure 7: Bringing wires through front plate.
TCWS.54NGST03D_210417-24
5056.425181D
Figure 8: Attaching the pilot assembly to the burner leg.
7