Town & Country Fireplaces TCWS.38NG03.C Скачать руководство пользователя страница 6

Fig #16

TCWS.38NG03.C 080709-12

WARNING

This conversion kit 
shall be installed by a 
qualified service agency 
in accordance with the 
manufacturer's instructions 
and all applicable codes 
and requirements of 
the authority having 
jurisdiction. 

If the information in these 
instructions is not followed 
exactly, a fire, explosion 
or production of carbon 
monoxide may result 
causing property damage, 
personal injury or loss of 
life. 

The qualified service 
agency is responsible for 
the proper installation of 
this kit. 

The installation is not 
proper and complete 
until the operation of the 
converted appliance is 
checked as specified in the 
manufacturer's instructions 
supplied with the kit.

If the unit is to be used with propane 
convert as follows using the compo-
nents supplied with this burner:

CAUTION

The gas supply and electrical power 
shall  be  shut  off  before  proceeding 
with the conversion.

Caution: 
 

Factory  supplied  components  must  be 
used to ensure correct input.  

 

After conversion confirm proper manifold 
pressure.

1.   If installed remove the glass media from 

the  burners. 

2.   If installed remove the burner from the 

burner tray. Gently lift up the left side of 
the  burner  and  disengage  the  venturi 
tube from the orifice. (Fig. #14)

3.  using a 1/2” wrench, undo the 
 

natural gas burner orifice, (Fig #15)

 

(marked 

#40

). Apply a small amount  

 

of pipe joint compound to the threads  

 

of the propane burner orifice 

 

(marked 

1.45mm

) to ensure a good  

 

seal, before screwing it into the fitting.

 

 

Loosen the primary air shutter screw, 
open  shutter  to  give  a  gap  of  1/8” 
(0.125”)  and    re-tighten.  Repeat  on 
other burner. (Fig. #15a)

4.    With  a  7/16”  wrench  loosen  the  pilot 

head on the pilot assembly. (Fig. #16)

Propane Conversion

Fig #15

Fig #14

Fig #15a

MAIN BuRNER 
(1.45mm) ORIFICES  (5022.8)

MINIMuM RATE SCREW (5005.015)

CONVERSION lABEl (5052.52087)

6

Содержание TCWS.38NG03.C

Страница 1: ...8 Series C These instructions are supplementary to the Installation and Operating Instructions supplied with the fireplace and should be kept together Refer to the Installation and Operating Instructions for proper gas supply safety requirements and operating instructions IMPORTANT THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOMEOWNER ...

Страница 2: ...re the fuel supply tube travels around the mounting leg towards the front of the firebox as shown Fig 1 2 Connect spark electrode wire ORANGE to the rear electrical bulk head fitting Connect the flame sensor wire WHITE to the front electrical bulk head fitting Fig 1 ORANGE WIRE Contents of Package Black Diamond Burner Installation 1 Burner tray Fig 1 1 5 lb GLASS MEDIA 2 BURNER ASSEMBLIES 1 PILOT ...

Страница 3: ...ebox using four screws Fig 2 CAUTION Ensure that all connections are gas tight 4 Bend side tabs on burner tray inwards about 20 or 1 2 Fig 4 5 Tilt the burner tray into the unit and place on top of the legs Attach pilot to burner tray Ensure pilot is tight to burner tray Fig 5 Fig 2 Fig 3 Fig 4 Fig 5 3 ...

Страница 4: ...evated slide it to the far right The primary air shutter shouldengagefullywiththemainorifice Test for connection by lightly prying at theendoftheburnerwithascrewdriver Repeat with left burner Fig 7 NOTE The burners should be tightly butted up against each other at the center to ensure correct operation 8 Place glass media into the burner tray and brush smooth so that a very light layer covers the ...

Страница 5: ...TCWS 38ng03 C 080709 12 10 Install front porcelain cover wide edge should face the front Fig 10 11 WIDE EDGE TO FRONT OF FIREPLACE Fig 10 Fig 11 5 ...

Страница 6: ...UTION The gas supply and electrical power shall be shut off before proceeding with the conversion Caution Factory supplied components must be used to ensure correct input After conversion confirm proper manifold pressure 1 If installed remove the glass media from the burners 2 If installed remove the burner from the burner tray Gently lift up the left side of the burner and disengage the venturi t...

Страница 7: ...n the valve Fig 19 The minimum rate screw is sealed with an O ring Use a thin bladed screwdriver to back the screw out past the limit of the threading At this point a groove on the screw body will be visible just above the valve body Insert a thin tool knife blade or fine screwdriver blade into the groove and gently pry the screw up 8 Replacetheminimumratescrewwiththe one provided in the propane c...

Страница 8: ...0 The center post should stay down Fig 22 Replace the rubber cap 11 Check all connections for leaks WARNING The access panel including gasket must be reinstalled after conversion installation or servicing has been completed Failure to do sowillcauseoverheating and premature failure of the control system 12 Fill in the date and the name of the person who performed the conversion in the white area o...

Страница 9: ...lant will be required to ensure a gas tight connection Note To test the gas pressure turn off the gas supply before removing the plug from the supply pressure test port or manifold pressure test port Verify gas pressures with the fireplace lit and on the highest setting supply Pressure MANIFOLD Pressure Fig 26 Correct gas pressure requirement Supply Pressure Natural Gas Propane Min Pressure 5 0 WC...

Страница 10: ...has reached operating temperature See Fig 27 for proper flame pattern Open primary air if the window glass and firebox have carbon accumulation and or the flames are long dark and stringy The shutter may also be opened to lessen the flame height NOTE Proper air shutter setting is required The flame should be just orange and lazy It should NEVER be set to create sooting on internal parts and window...

Страница 11: ...G03 C 2 GLASS MEDIA TCRP 501201 3 FUEL SUPPLY TUBE 5019 223 4 PILOT ASSEMBLY TCRP 5005025C ITEM DESCRIPTION PART NO 5 ORIFICE NATURAL GAS 40 5022 3 6 PROPANE CONVERSION KIT TCWS 38LPCE01 WHEN ORDERING INCLUDE PART NUMBER WITH DESCRIPTION Replacement Parts 1 KIT CONTENTS 1 1 4 1 1 5 1 1 3 4 11 ...

Страница 12: ...Technical support 1 250 748 1184 Web site www townandcountryfireplaces net 2975 Allenby Rd Duncan BC V9L 6V8 Printed in Canada ...