310317-20 TCVT.PVCV
5056.42665-A
Vertical vent pipe:
1.5 in. (38mm)
Horizontal vent pipe: Top
1.5 in. (38mm)
Sides
1.5 in. (38mm)
Bottom
1.5 in. (38mm)
All other clearances are as per the fireplace installation instructions.
VENT PIPE
This kit uses either Simpson Duravent GS direct vent pipe, Secure Vent direct vent pipe, Selkirk Direct-temp
vent pipe or ICC Excel Direct vent pipe with a 5” inner pipe and an 8” outer pipe. For part numbers see the
table of venting components on page 10 of this manual.
CAUTION: The adjustable vent restrictor located on the underside of the firebox top must be fully open.
The vertical standoff can only be installed on a flat surface. Sloped surfaces require the construction of a
chase which provides the minimum interior, square opening of 11” x 11” for the venting and wiring to pass
through. Flat roofs may require a chase depending on local codes and roof construction. (If in doubt check
with local inspector). The terminal must be located in accordance with the clearances outlined in Figure 1.
under no circumstances shall a rheostat be used to alter the voltage supply to this unit.
Minimum Clearances to Combustibles
3
Vertical (Through Roof) Venting
Installation:
All part numbers in the following section are shown in Figure 3.
1. Place the flashing onto the chase and seal using silicone.
2. Put a bead of silicone on the underside of the vertical standoff and place it on top of the flashing. Align the
eight holes and secure both parts to the chase using eight #8 x 1 1/2” screws provided.
3. Install the drip shield onto the top of the vertical standoff using a bead of silicone between the two. Do not
screw this part in place.
4. Bring the 14-2 electrical wire (not supplied) up through the holes in both the flashing and the drip shield
leaving at least 12” of excess wire above the drip shield.
5. IMPORTANT: Attach an appropriate length(s) of the vent to the power vent terminal, sufficient to pass
through the chase.
NOTE: DO NOT CONNECT AN ADJUSTABLE LENGTH VENT PIPE TO THE TERMINAL.
6. Seal the connection of the first length of pipe at the terminal and any other pipe to pipe joint by both
screwing and taping the outside joint using high temperature foil tape.
7. Remove the junction box cover.
8. Remove and discard the exhaust outlet.