TO HOME
AUTOMATION
SYSTEM
NOTE:
•
Digital I/O must be connected to a dry contact relay.
•
Analog flame and light input through 0 - 10 volt DC
signal scaled as follows:
Low = 1 volt
High = 10 volts
NOTE:
When a signal has been supplied by the home automation system, the fireplace control
will repeat the signal every 2 hours or until a new command has been received.
The home automation feature supplied with this fireplace is capable
of controlling the flame and light on/off function with the use of a dry
contact relay common to home automation systems. Furthermore, the
flame and light level may be modulated from high to low using the
0 - 10 volt analog output available on most home automation systems.
(Figure 36) shows the wire designations required to connect the fire-
place to a home automation system (wire not supplied).
Figure 35: Complete communication wiring.
Figure 36: Home automation side wiring diagram.
19
5056.427D
TC36_D & TC36_DAR_101215-52
Home Automation