background image

MAIN BURNER 
(#45) ORIFICE  (5021.34)

MINIMUM RATE SCREW (5005.015)

Propane Conversion

If the unit is to be used on propane, 
conver t as follows using the 
components supplied with this 
burner:

CAUTION

The gas supply and electrical power 
must be shut off before proceeding 
with the conversion.

Fig. # 15

Fig. # 16

Fig. # 14

WARNING

This conversion kit shall be 
installed by a qualifi ed 
service agency in 
accordance with the 
manufacturer's instructions 
and all applicable codes 
and requirements of the 
authority having 
jurisdiction. 

If the information in these 
instructions is not followed 
exactly, a fi re, explosion or 
production of carbon 
monoxide may result 
causing property damage, 
personal injury or loss of 
life. 

The qualifi ed service 
agency is responsible for 
the proper installation of 
this kit. 

The installation is not 
proper and complete un-
til the operation of the 
converted appliance is 
checked as specifi ed in the 
manufacturer's instructions 
supplied with the kit.

1. 

Ensure the burner, pilot and gas 

 

supply are turned off, and the    

 

appliance has cooled.

2.  

Remove the two screws securing the 
manifold assembly to the burner. 

 (Fig. 

#14)

3.  

Remove the manifold assembly from the 
burner. (Fig. #15)

4.  

 With a ½” wrench remove the natural gas 
orifi ce (#30) and replace with propane 
orifi ce (#45) (our part # 5021.34) 

 (Fig. 

#16) 

5. 

Fully open the primary air shutter.

6. 

Reinstall the manifold assembly

Note: Factory supplied components must 
be used to ensure correct input.  
After conversion confi rm proper manifold 
pressure.

CONVERSION LABEL (5052.5208)

9

TC36.NG06C 050411-16

Содержание TC36 CHALET II

Страница 1: ...ns are supplementary to the Installation and Operating Instructions supplied with the fireplace and should be kept together Refer to the Installation and Operating Instructions for proper gas supply safety requirements and operating instructions TC36 CHALET II BURNER KIT INSTALLATION INSTRUCTIONS PART TC36 NG06C For use with Model TC36 Series C ...

Страница 2: ...ots in the burner overthetwoscrewslocatedinthefirebox base Fig 1 1a 2 Slide the burner back to engage the screws in the small part of the keyhole slot and tighten screws Fig 1b 3 Remove access cover from side of firebox Fig 1c Fig 1a Fig 1b SCREWS Fig 1 Fig 1c If this fireplace is to be used on Propane please convert prior to installtion See pages 9 11 ...

Страница 3: ...plate and gasket to the firebox 2 screws Attach the ignition and sensor wires to the module Red end to the connector marked by the reddot whiteendtotheconnectormarked by the white dot Fig 2 Fig 3 Fig 2 Burner Grate Installation RED END TO RED DOT WHITE END TO WHITE DOT MODULE Fig 3 ...

Страница 4: ...nd tighten Fig 4 Ensure the connections are gas tight Conceal the spark and sensor wires below the supply tubes A panel set must now be installed See InstallationandOperatingInstructions manual for details 6 Position the slots of the grate securing brackets over the holes in the floor shield and secure with the two screws Fig 5 Fig 4 ...

Страница 5: ...cover up gas lines and brackets Note Ember material placement and amount will affect flame appear ance More ember material results in lower flame height Add or remove as needed until d e s i re d flame affect Fig 6 Gas plumbing and vent connections should be completed before proceeding The logs are are fragile and should be handled with care Unpack and inspect log set There should be a total of 7 ...

Страница 6: ...6 TC36 NG06C 050411 16 Fig 9 Fig 8 LOG 2 LOG 3 ...

Страница 7: ...7 TC36 NG06C 050411 16 Fig 11 Fig 10 LOG 4 LOG 5 ...

Страница 8: ...8 TC36 NG06C 050411 16 GRATE INSTALLATION Fig 13 LOG 7 Note Improper placement of logs will cause sooting on internal parts and glass Fig 12 LOG 6 ...

Страница 9: ...mage personal injury or loss of life The qualified service agency is responsible for the proper installation of this kit The installation is not proper and complete un til the operation of the converted appliance is checked as specified in the manufacturer s instructions supplied with the kit 1 Ensure the burner pilot and gas supply are turned off and the appliance has cooled 2 Remove the two scre...

Страница 10: ... a half turn Fig 17 8 Slide the pilot adjustment band over and ensure that the hole in the orifice band is showing Fig 19 shows NG position Fig 20 shows LP position 9 Removetheminimumratescrewlocated in the valve Fig 21 Fig 20 Fig 21 Fig 17 Fig 19 10 TC36 NG06C 050411 16 M ra HOLE ...

Страница 11: ...ssure regulator Fig 23 12 Press down on the center post and rotate 90 The center post should stay down Fig 24 Replace the rubber cap 13 Fill in the date and the name of the person who performed the conversion in the white area on the conversion label Peel off the protective backing and apply the conversion label directly over the gas specifications on the rating label 14 Attach the access panel to...

Страница 12: ...ce the plug Thread sealant will be required to ensure a gas tight connection Correct gas pressure requirement Supply Pressure Natural Gas Propane For purpose of input adjustment Minimum 5 0 WC 12 5 WC Maximum 13 9 WC 13 9 WC Manifold Pressure Maximum 3 8 WC 11 0w WC Minimum 2 1 WC 5 5 WC Note To test the gas pressure turn off the gas supply before removing the plug from the supply pressure test po...

Страница 13: ...ay also be opened to enhance the Ember Material glow and lessen the flame height Caution Burner area may be hot Turn off the fireplace and allow the unit to cool before proceeding Caution Proper air shutter setting is a must The flame should be just orange and lazy It should NEVER be set to create sooting on internal parts and glass Burner Flame Adjustment To Adjust Fig 29 1 Open and remove window...

Страница 14: ...LOT SHIELD 1e TC42 NG01 BURNER WELD 1f MANIFOLD 1g 1 2 PIPE TO 1 2 TUBE CONNECTION 1h PILOT BRACKET 2a LOG 1 2b LOG 2 2c LOG 3 2d LOG 4 2e LOG 5 2f LOG 6 2g LOG 7 KIT CONTENTS 3 ORIFICE NATURAL GAS 4 PILOT ASSEMBLY 5 MAIN SUPPLY TUBE 6 PILOT TUBE 2 7 PCS LOG SET EMBER MATERIAL Not shown 2a LOG 1 2b LOG 2 2c LOG 3 2d LOG 4 2e LOG 5 2f LOG 6 2g LOG 7 3 ORIFICE NATURAL GAS 30 4 PILOT ASSEMBLY CONVERT...

Страница 15: ...15 TC36 NG06C 050411 16 ...

Страница 16: ...TECHNICAL SUPPORT 1 250 748 1184 www townandcountryfireplaces net 2975 Allenby Rd Duncan BC V9L 6V8 Printed in Canada ...

Отзывы: